m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2020

Transfemoral transcatheter puncture of interventricular septum in a swine model: A novel transfemoral-venous access to left ventricle with the assistance of arterio-venous circuit.

СтатьяVideo-Audio MediaНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yan Chaowu, Wan Linyuan, Li Li, Li Hua, Du Baopeng, Hao Shijie

Аннотация

OBJECTIVE: Via subclavian/jugular vein, successful puncture of interventricular septum (IVS) has been achieved transvenously. However, the approach was limited by acute entry-angle. The study was conducted to investigate a novel transcatheter puncture of IVS via femoral access and transfemoral-venous access to left ventricle (LV) through IVS.

METHODS: Via femoral artery, transcatheter puncture of mid-IVS was performed with a custom-made nickel-titanium needle and 6F-sheath in 16 healthy mini-swine. Then femoral arterio-venous circuit was established through IVS. After pre-dilation of IVS, a 20F-sheath was introduced into LV transvenously over-the-guidewire in 15 swine. Furthermore, transfemoral-venous TAVR was attempted with the approach in another swine. IVS was evaluated postoperatively and was further confirmed pathologically 2 months later.

RESULTS: All transcatheter puncture of IVS was performed successfully in LV and the mid-IVS thickness was 7.67 ± 0.98 mm. In all swine, femoral arterio-venous circuit was established via IVS, and a 20F-sheath was introduced into LV and aorta transfemoral-venously (entry-angle: 145.3 ± 12.2° in front view). After the procedure, there was one swine with moderate tricuspid-regurgitation and five swine with mild residual-shunt (2.6 ± 0.7 mm). Two months later, residual-shunt was still detected in three swine and the communication was confirmed pathologically. In other swine, no defect occurred and replacement-scar was identified along puncture-tract. In the swine underwent transfemoral-venous TAVR, prosthetic valve was deployed successfully with good function.

CONCLUSIONS: Transfemoral transcatheter puncture of IVS is feasible and safe in a swine model, and large sheath can be introduced into LV transfemoral-venously using the novel access with the aid of vessel circuit.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты