Efficacy of a novel low-cost torchlight transcorneal transillumination for diode laser transscleral cyclophotocoagulation in adult glaucoma.

Thattaruthody Faisal, Chauhan Neha, Choudhary Sandeep, Raj Srishti, Pandav Surinder Singh, Kaushik Sushmita

СтатьяПеревод в очереди

Аннотация

PURPOSE: To study the outcomes of diode laser transscleral cyclophotocoagulation (TSCPC) with trans-corneal transillumination using a novel low-cost torchlight method in refractory glaucoma.

METHODS AND ANALYSIS: This prospective interventional study included patients with refractory glaucoma who underwent TSCPC with trans-corneal transillumination (TSCPC-TI) using a novel low-cost torchlight method. Patients completing a minimum 6-month follow-up were analyzed. They were compared to a historical control group of patients who underwent TSCPC without transillumination (TSCPC-No TI) at 6-month follow-up period. We analyzed the mean laser energy delivered, post-laser intraocular pressure (IOP) reduction, number of antiglaucoma medications (AGM), the requirement of retreatment and complications of the procedure in both groups.

RESULTS

32 eyes of 29 patients comprised the TSCPC-TI group and were compared with 39 eyes of 37 patients in the TSCPC-No TI group. The TSCPC-TI group required lower energy than the TSCPC-No TI group (46.15 ± 22.8 Vs 80.65 ± 56.1 J p < 0.001). At 6-month follow-up, the TSCPC-TI group required lesser AGM for IOP control (2.33 ± 1.02 vs 3.02 ± 1.32 p = 0.01). There was a significantly reduced dependence of oral acetazolamide in the TSCPC-TI group at 6 months follow-up (15.6% vs 41% p = 0.03%). The success and response rates were 71.8% Vs 23.1%; p < 0.0001 and 87.5% Vs 51.2%; p = 0.001 significantly high in the TSCPC-TI group. The TSCPC-No TI group had a significantly high failure rate (12.5% Vs 48.2% p = 0.001). Hypotony (n = 1) and phthisis (n = 2) were noted TSCPC-No TI group.

CONCLUSIONS

TSCPC with transillumination with a low-cost torchlight resulted in a more efficient and effective cycloablation than TSCPC without transillumination.

Для цитирования: Thattaruthody Faisal, Chauhan Neha, Choudhary Sandeep, Raj Srishti, Pandav Surinder Singh, Kaushik Sushmita. Efficacy of a novel low-cost torchlight transcorneal transillumination for diode laser transscleral cyclophotocoagulation in adult glaucoma.. European journal of ophthalmology. 2024. DOI: 10.1177/11206721241253305.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.