Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2012
Impact of respiration on electroanatomical mapping of the right atrium: implication for cavotricuspid isthmus ablation.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
de Ruvo Ermenegildo, Dottori Serena, Sciarra Luigi, Rebecchi Marco, Alessio Borrelli, Antonio Scarà, De Luca Lucia, Martino Anna Maria, Guarracini Fabrizio, Fagagnini Alessandro, Lioy Ernesto, Calò Leonardo
Аннотация
PURPOSE: Cavotricuspid isthmus (CTI) ablation for typical atrial flutter (AFL) has become the preferred treatment for this arrhythmia. The aims of this study were to assess the impact of respiratory gating (RG) on electroanatomical mapping of CTI and to assess the efficiency of CTI ablation guided by the Carto3® system equipped with the new respiration gating software.
METHODS: Forty-four consecutive patients (mean age, 60 ± 13 years; 25 male) undergoing cavotricuspid ablation for symptomatic common AFL were randomly assigned to CARTO™ mapping with or without enabling RG module (Group A, RG OFF, Group B, RG ON).
RESULTS: A significant reduction in mean RA volume, CTI central length and CS ostium maximum diameter has been observed in the RG maps. The mean total procedural, fluoroscopy and radiofrequency (RF) time were 102.9 ± 35.3, 10.6 ± 3.3, 22.9 ± 14.2 min in group A and 75.3 ± 21.7, 3.6 ± 4.5, 10.4 ± 5.7 min in group B, respectively (p < 0.05).
CONCLUSIONS: Electroanatomical mapping systems' accuracy may be strongly influenced by respiration movements. The current study showed that automatic respiratory gated acquisition resulted in a better visualization of CTI, and this determines a relevant reduction in fluoroscopy and RF times.
METHODS: Forty-four consecutive patients (mean age, 60 ± 13 years; 25 male) undergoing cavotricuspid ablation for symptomatic common AFL were randomly assigned to CARTO™ mapping with or without enabling RG module (Group A, RG OFF, Group B, RG ON).
RESULTS: A significant reduction in mean RA volume, CTI central length and CS ostium maximum diameter has been observed in the RG maps. The mean total procedural, fluoroscopy and radiofrequency (RF) time were 102.9 ± 35.3, 10.6 ± 3.3, 22.9 ± 14.2 min in group A and 75.3 ± 21.7, 3.6 ± 4.5, 10.4 ± 5.7 min in group B, respectively (p < 0.05).
CONCLUSIONS: Electroanatomical mapping systems' accuracy may be strongly influenced by respiration movements. The current study showed that automatic respiratory gated acquisition resulted in a better visualization of CTI, and this determines a relevant reduction in fluoroscopy and RF times.