Prospective study of serum and aqueous humour anti-Hsp70.1 IgG antibody levels in ocular toxoplasmosis.
Аннотация
AIMS: We evaluate whether the serum and aqueous humour (AH) level of IgG anti-Hsp70.1 antibodies improved the biological diagnosis of ocular toxoplasmosis.
METHODS AND
RESULTS
In this prospective cross-sectional and multicentre study, serum and AH were collected at the time of active uveitis. Anti-Hsp70.1-antibody levels were determined by ELISA. Patients with confirmed (Group A1, n = 21) or suspected ocular toxoplasmosis (group A2, n = 30) were enrolled, as well as a control group of patients with cataract (group B, n = 42). Serum IgG anti-Hsp70.1 antibody levels were not significantly different within the group of uveitis patients (A1, n = 21 vs A2, n = 30, P = .8) and were significantly associated with the affected retinal zone (P = .006) and with the size of the retinal lesion (P = .03). Serum anti-Hsp70.1 antibody level was positive in 10 out of the 18 patients of group A2. Significant anti-Hsp-70.1 antibody level in AH was reported in only three patients (3 eyes) with confirmed ocular toxoplasmosis.
CONCLUSION
While the level of IgG anti-Hsp-70.1 antibody in AH did not improve the laboratory diagnosis of ocular toxoplasmosis, its level in serum was of major significance for retinal damage diagnosis.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.