MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euae212

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024

Systematic review and meta-analysis on the impact on outcomes of device algorithms for minimizing right ventricular pacing.

Mei Davide Antonio, Imberti Jacopo Francesco, Vitolo Marco, Bonini Niccolò, Serafini Kevin, Mantovani Marta, Tartaglia Enrico, Birtolo Chiara, Zuin Marco, Bertini Matteo, Boriani Giuseppe

СтатьяСистематический обзорМетаанализПеревод в очереди

Аннотация

AIMS: Physiological activation of the heart using algorithms to minimize right ventricular pacing (RVPm) may be an effective strategy to reduce adverse events in patients requiring anti-bradycardia therapies. This systematic review and meta-analysis aimed to evaluate current evidence on clinical outcomes for patients treated with RVPm algorithms compared to dual-chamber pacing (DDD).

METHODS AND

RESULTS

We conducted a systematic search of the PubMed database. The predefined endpoints were the occurrence of persistent/permanent atrial fibrillation (PerAF), cardiovascular (CV) hospitalization, all-cause death, and adverse symptoms. We also aimed to explore the differential effects of algorithms in studies enrolling a high percentage of atrioventricular block (AVB) patients. Eight studies (7229 patients) were included in the analysis. Compared to DDD pacing, patients using RVPm algorithms showed a lower risk of PerAF [odds ratio (OR) 0.74, 95% confidence interval (CI) 0.57-0.97] and CV hospitalization (OR 0.77, 95% CI 0.61-0.97). No significant difference was found for all-cause death (OR 1.01, 95% CI 0.78-1.30) or adverse symptoms (OR 1.03, 95% CI 0.81-1.29). No significant interaction was found between the use of the RVPm strategy and studies enrolling a high percentage of AVB patients. The pooled mean RVP percentage for RVPm algorithms was 7.96% (95% CI 3.13-20.25), as compared with 45.11% (95% CI 26.64-76.38) of DDD pacing.

CONCLUSION

Algorithms for RVPm may be effective in reducing the risk of PerAF and CV hospitalization in patients requiring anti-bradycardia therapies, without an increased risk of adverse symptoms. These results are also consistent for studies enrolling a high percentage of AVB patients.

Для цитирования: Mei Davide Antonio, Imberti Jacopo Francesco, Vitolo Marco, Bonini Niccolò, Serafini Kevin, Mantovani Marta, Tartaglia Enrico, Birtolo Chiara, Zuin Marco, Bertini Matteo, Boriani Giuseppe. Systematic review and meta-analysis on the impact on outcomes of device algorithms for minimizing right ventricular pacing.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2024. DOI: 10.1093/europace/euae212.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.