m+Medelevator.RU
← Поиск публикаций
BMJ open respiratory research · 2026

Portable low-flow nasal oxygen versus ambient air in patients with chronic lung disease and exercise-induced hypoxaemia: a randomised controlled crossover non-inferiority trial.

СтатьяEquivalence TrialРандомизированное исследованиеPragmatic Clinical TrialНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lichtblau Mona, Wick Carmen, Titz Anna, Müller Julian, Schneider Simon Raphael, Hertig Dinah, Bousraou Zoe, Vella Alessandro, Furian Michael, Kohler Malcolm, Schwarz Esther Irene, Ulrich Silvia

Аннотация

BACKGROUND: Exercise-induced desaturation is a common symptom in chronic lung disease (CLD) and is associated with functional limitation and increased mortality. Although portable low-flow supplemental oxygen therapy (SOT) is commonly prescribed for exercise-induced hypoxaemia, evidence for SOT to improve performance is inconsistent.

METHOD: This pragmatic, randomised, controlled, non-inferiority crossover trial enrolled patients with chronic obstructive pulmonary and interstitial lung disease who exhibited exercise-induced oxygen desaturation of >3%. Each patient performed two 6-minute walk distance (6MWD) tests in randomised order: one breathing ambient air and one using low-flow SOT delivered by a portable backpack concentrator (1-2 L/min). The primary outcome was 6MWD, secondary outcomes included perceived exertion and preference of the interventions. A predefined non-inferiority margin of 35 m was used.

RESULTS: Forty patients were enrolled (mean age 66±13 years; 14 women; 20 with chronic obstructive pulmonary disease (COPD), 20 with interstitial lung disease (ILD)). The mean difference in 6MWD between ambient air and SOT was 0 m (95% CI -14 to 13 m; p<0.001 for non-inferiority). Secondary outcomes demonstrated significantly lower dyspnoea scores with SOT both overall and within COPD/ILD subgroups. Patient preferences were split, with 49% favouring ambient air and 51% preferring SOT. A clinically meaningful improvement in 6MWD of >35 m was found in five patients.

CONCLUSION: In patients with CLD and exercise-induced desaturation, ambient air was non-inferior to pulsed low-dose SOT by portable concentrator in 6MWD, but SOT improved dyspnoea. These findings highlight the need for more effective, patient-acceptable oxygen delivery systems and further research to identify responders to SOT.

TRIAL REGISTRATION NUMBER: NCT06385301.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты