MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000503441

Медицинская библиотека · Case reports in ophthalmology · 2019

Clinical Evaluation of the NS Endo-Inserter, a Novel Donor Inserter for Descemet's Stripping Automated Endothelial Keratoplasty.

Kobayashi Akira, Yokogawa Hideaki, Mori Natsuko, Nishino Tsubasa, Sugiyama Kazuhisa

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: This study investigated the clinical outcomes achieved with a newly developed donor inserter (NS Endo-Inserter [NSI], HOYA Co., Ltd., Tokyo, Japan) for Descemet's stripping automated endothelial keratoplasty (DSAEK) in Japanese eyes with bullous keratopathy secondary to argon laser iridotomy (BK-ALI). The NSI device utilizes pressure flow to push the DSAEK donor tissue into the anterior chamber.

METHODS

Six eyes of 6 patients (1 male, 5 females; mean age, 78.5 years) with BK-ALI were enrolled. Donor tissue was pushed into the anterior chamber using the NSI. Intraoperative complications, graft dislocation, and iatrogenic primary graft failure were recorded for all eyes. Six-month postoperative central donor endothelial cell densities (ECD) were measured prospectively and compared with preoperative values, along with 6-month best corrected visual acuity (BCVA).

RESULTS

In all cases, donor loading onto the NSI spatula and donor insertion into the anterior chamber using the NSI was smooth and successful; no intraoperative complications were noted. There were no cases of graft dislocation or IPGF. Postoperative ECD was 2,187.2 cells/mm2 (mean loss, 14.8%) and mean BCVA increased from 0.27 decimal to 0.8 at 6 months.

CONCLUSION

In this small preliminary case series, clinical outcomes for patients with BK-ALI undergoing DSAEK using the NSI were comparable or better than those achieved with conventional DSAEK insertion techniques.

Для цитирования: Kobayashi Akira, Yokogawa Hideaki, Mori Natsuko, Nishino Tsubasa, Sugiyama Kazuhisa. Clinical Evaluation of the NS Endo-Inserter, a Novel Donor Inserter for Descemet's Stripping Automated Endothelial Keratoplasty.. Case reports in ophthalmology. 2019. DOI: 10.1159/000503441.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.