DOI 10.31661/gmj.vi.3900

Медицинская библиотека · Galen medical journal · 2025

Comparison of the Accuracy of CBCT and MDCT Images in Measuring the Thickness of the Posterior Footplate of the Middle Ear in Iranian :

Sharifi Shooshtari Sanaz, Saki Nader, Roozbahani Zohreh, Farahmandfar Kowsar, Bagheri Nila

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Advancements in radiological imaging have transitioned from two-dimensional radiography to three-dimensional cone beam computed tomography (CBCT), offering high spatial resolution with reduced radiation doses compared to multidetector computed tomography (MDCT). While MDCT remains the standard for detailed visualization of bony structures like the ossicular chain, its higher radiation exposure is a concern. This study compares the accuracy of high-resolution (HR) and low-resolution (LR) CBCT with MDCT in measuring the thickness of the posterior footplate of the middle ear to identify a reliable, low-radiation alternative.

MATERIALS AND

METHODS

Twelve adult human temporal bones from Imam Khomeini Hospital's ENT Department were imaged using HR-CBCT, LR-CBCT (Jundishapur Dental School), and MDCT (Siemens Sensation 64-slice). Standardized imaging protocols ensured reproducibility, with measurements of posterior footplate thickness conducted in axial, coronal, and sagittal planes by two blinded radiologists. Data were analyzed using SPSS v23, with inter-modality agreement assessed via Kappa coefficient and differences evaluated with the McNemar test.

RESULTS

Mean posterior footplate thickness was 2.38 mm (HR-CBCT), 2.37 mm (LR-CBCT), and 2.23 mm (MDCT), with no significant differences (P0.05). HR-CBCT and LR-CBCT showed comparable accuracy to MDCT.

CONCLUSION

CBCT, particularly HR-CBCT, offers a reliable, lower-radiation alternative to MDCT for otologic imaging, maintaining high resolution for middle ear assessments.

Для цитирования: Sharifi Shooshtari Sanaz, Saki Nader, Roozbahani Zohreh, Farahmandfar Kowsar, Bagheri Nila. Comparison of the Accuracy of CBCT and MDCT Images in Measuring the Thickness of the Posterior Footplate of the Middle Ear in Iranian :. Galen medical journal. 2025. DOI: 10.31661/gmj.vi.3900.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.