MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-024-01914-8

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2024

Catheter ablation for atrial fibrillation in patients with prior left atrial appendage occlusion device.

Kewcharoen Jakrin, Shah Kuldeep, Bhardwaj Rahul, Contractor Tahmeed, Ramsingh Davendra, Turagam Mohit K, Mandapati Ravi, Lakkireddy Dhanunjaya, Garg Jalaj

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The safety and efficacy of CA for AF and left-sided atrial arrhythmias (AA) in patients with left atrial appendage occlusion (LAAO) devices are lacking.

METHODS

This is a single-center retrospective registry that included all patients with prior LAAO who underwent catheter ablation for AF or left-sided atrial arrhythmia from January 2020-January 2023. The primary outcomes were procedure-related complications, device-related complications, AA recurrence, and stroke.

RESULTS

A total of 30 patients with prior LAAO were included in the analysis (mean age 75.1 ± 7.1 years old, 50% male, mean CHA2DS2-VASc score 4 ± 1.6, 46.7% paroxysmal AF, 73.3% had prior AF ablation, mean time to ablation 475 ± 365 days). 93.3% (n = 28) and 6.6% (n = 2) patients had ablation for AF (46.7% paroxysmal, 36.7% persistent, 10% long-standing persistent) and left-sided atrial tachycardia, respectively. 16.7% (n = 5) patients underwent ablation along the left atrial appendage ostium, and 3.3% (n = 1) underwent Vein of Marshall alcohol ablation. There were 3 (10%) peri-procedural complications (1 access hematoma and two pericardial effusions requiring intervention-none related to left atrial appendage ostium or alcohol ablation). During the mean follow-up of 440 ± 379 days, 40% (n = 12) patients had AA recurrence (91.6% AF, 8.3% atrial tachycardia), of which five patients needed repeat ablation, and two patients were readmitted for heart failure. There was no stroke or any device-related complications, including new peri-device leaks or device-related thrombosis in patients who had follow-up imaging studies (n = 11, 36.7%).

CONCLUSION

Catheter ablation for AF (including VoM alcohol ablation) in patients with prior LAAO devices is feasible and safe with favorable outcomes.

Для цитирования: Kewcharoen Jakrin, Shah Kuldeep, Bhardwaj Rahul, Contractor Tahmeed, Ramsingh Davendra, Turagam Mohit K, Mandapati Ravi, Lakkireddy Dhanunjaya, Garg Jalaj. Catheter ablation for atrial fibrillation in patients with prior left atrial appendage occlusion device.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2024. DOI: 10.1007/s10840-024-01914-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.