MedElevator Войти в исследования
← Поиск публикаций

DOI 10.48095/cccg2026173

Медицинская библиотека · Ceska gynekologie · 2026

Junctional zone thickness on magnetic resonance imaging - a non-invasive diagnostic method for adenomyosis and beyond.

Horasanl Jule Eriç, Akkuş Fatih, Yılmaz Pinar Diydem, Kadıyoran Cengiz, Polat Ecenur Çetinkuş

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Adenomyosis is a prevalent gynecologic disorder involving ectopic endometrial tissue within the myometrium. Magnetic resonance imaging (MRI) enables non-invasive diagnosis, yet the role of junctional zone (JZ) thickness in predicting coexisting intrauterine pathologies remains uncertain. This study evaluated the diagnostic and predictive value of MRI-based JZ thickness in hysterectomy-confirmed adenomyosis.

MATERIALS AND

METHODS

This retrospective study included 420 patients who underwent hysterectomy with preoperative MRI between 2020 and 2025. JZ thickness was measured on sagittal T2-weighted images, and histopathological findings were recorded. Logistic regression analyses were performed to identify independent predictors of intrauterine pathologies. Diagnostic accuracy was assessed using receiver operating characteristic (ROC) curves.

RESULTS

The mean JZ thickness was 17.5 ± 3.8 mm. Histopathological evaluation confirmed adenomyosis in 97.1% of cases, with coexisting lesions including myomas (44.5%), endometrial polyps (7.9%), simple hyperplasia (6.2%), atypical hyperplasia (1.9%), and endometrial cancer (2.4%). JZ thickness demonstrated strong positive correlations with polyps (R = 0.46; P < 0.001), simple hyperplasia (R = 0.55; P < 0.001), atypical hyperplasia (R = 0.49; P < 0.001), and myomas (R = 0.38; P < 0.001). Logistic regression identified JZ thickness as the most consistent independent predictor of intrauterine lesions, with an odds ratio of 1.70 for atypical hyperplasia (95% CI 1.11-2.60; P = 0.014). ROC analysis revealed excellent discriminative ability for simple hyperplasia (AUC = 0.842), atypical hyperplasia (AUC = 0.888), and polyps (AUC = 0.840), while predictive performance for myomas was moderate (AUC = 0.661).

CONCLUSIONS

MRI-based measurement of JZ thickness is a reliable, non-invasive biomarker for adenomyosis, demonstrating an additional predictive value for coexisting premalignant intrauterine pathologies. Incorporating JZ thickness thresholds into routine imaging evaluation may enhance risk stratification, reduce unnecessary invasive procedures, and inform about personalized management strategies in women with adenomyosis.

Для цитирования: Horasanl Jule Eriç, Akkuş Fatih, Yılmaz Pinar Diydem, Kadıyoran Cengiz, Polat Ecenur Çetinkuş. Junctional zone thickness on magnetic resonance imaging - a non-invasive diagnostic method for adenomyosis and beyond.. Ceska gynekologie. 2026. DOI: 10.48095/cccg2026173.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.