MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41467-026-76932-3

Медицинская библиотека · Nature communications · 2026

Frequency resonance amplification in ultrasound-induced long-lasting afterglow.

Zheng Guang-Song, Lou Qing, Shen Cheng-Long, Jiang Tian-Ci, Song Run-Wei, Cheng Zhe, Dong Lin, Shan Chong-Xin

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Ultrasound-induced afterglow has emerged as a promising modality for in vivo imaging, yet achieving sufficient afterglow brightness remains a challenge. Here, we report the inaugural realization of ultrasound-induced afterglow from carbon nanodots using engineered carbon nanodots, the elucidation of the resonance amplification mechanism during the ultrasound process, and the facilitation of high-contrast tumor imaging and precise resection. Through ultrasound frequency matching, we achieved up to 51-fold enhancement in sonoluminescence from carbon nanodots as fluorophore matrice, far surpassing the ultrasound-induced conventional organic polymer-based afterglow materials. Experimental and finite element analyses reveal an inverse monotonic relationship between ultrasound frequency and matrix dimensions, where resonant ultrasound enhances reactive oxygen species generation, leading to intermediate oxidation-derived near-infrared afterglow lasting over 240 min following a single 2-min ultrasound pulse. With significant amplification in afterglow brightness via precise frequency decoding, this approach evokes a 2.5 cm tissue penetration enabling high-contrast tumor imaging and precise resection in animal models, outperforming conventional optical-excited afterglow agents and fluorescence imaging. Our work elucidates the mutual size-frequency selection mechanism in ultrasound-induced afterglow and establishes a non-invasive, sensitive platform for advanced bioimaging and therapeutic monitoring.

Для цитирования: Zheng Guang-Song, Lou Qing, Shen Cheng-Long, Jiang Tian-Ci, Song Run-Wei, Cheng Zhe, Dong Lin, Shan Chong-Xin. Frequency resonance amplification in ultrasound-induced long-lasting afterglow.. Nature communications. 2026. DOI: 10.1038/s41467-026-76932-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.