m+Medelevator.RU
← Поиск публикаций
Scientific reports · 2024

Functional outcomes and quality of life after AcrySof IQ Vivity intraocular lens implantation in a real-world study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Giannuzzi Federico, Carlà Matteo Mario, Margollicci Fabio, Di Stefano Gaetano, Molle Andrea, Hu Lorenzo, Boselli Francesco, Pagliara Monica Maria, Lepore Domenico, Molle Fernando, Rizzo Stanislao

Аннотация

The extended depth-of-focus AcrySof IQ Vivity intraocular lens technology offers promising features for presbyopia management, evaluated in this research in a 6 months real-world setting. Prospective interventional mono-centric study including 40 patients who underwent elective bilateral phacoemulsification. We performed one pre-operative visit (V0) and one evaluation six months post-operatively (V1), evaluating uncorrected and corrected visual acuity for near (UNVA/CNVA), intermediate (UIVA/CIVA) and far (UDVA/UCVA), slit-lamp evaluation, tomography with static pupillometry, endothelial cell count and contrast sensitivity chart. In order to assess post-operative Quality of Life, we administered the patients McAlinden's Quality of Vision test and Morlock's Patient-Reported Spectacle Independence Questionnaire. We divided eyes in with Toric-IOL and with non-Toric IOL. A total of 36 eyes received non-tonic IOL implantation, whereas 44 eyes received toric IOL implantation. There were no statistically significant disparities observed in visual outcome measures and contrast sensitivity between the toric group and the non-toric group. Furthermore, we assessed the predictive preoperative refractive astigmatism (PPRA) and residual refractive astigmatism (RRA) in both cohorts, and no statistical significance was found between the two cohorts (p = 0.08). Twenty-one (53%) patients reported total independence from their glasses at all distances. The mean difference between the predicted and measured refractive error, as calculated by spherical equivalent, was 0.09 D. AcrySof IQ Vivity is a well-tolerated and effective IOL with optimal refractive target for both distant and intermediate vision, needing slight spherical addition for the best near vision. Great questionnaire-based satisfaction was reported by the patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты