Retina (Philadelphia, Pa.) · 2020
ONE-YEAR OUTCOMES OF A NOVEL SURGICAL TECHNIQUE FOR SUTURELESS INTRASCLERAL FIXATION OF A THREE-PIECE INTRAOCULAR LENS USING A 30-GAUGE NEEDLE.
СтатьяVideo-Audio MediaНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bonnell Alyssa C, Polo Richard N, Shah Sumit P, Fine Howard F, Prenner Jonathan L
Аннотация
PURPOSE: To present the 1-year results of a surgical technique for the sutureless intrascleral fixation of a 3-piece intraocular lens using a 30-gauge needle.
METHODS: A retrospective chart review of a consecutive series of 9 eyes of 8 patients who underwent sutureless intrascleral fixation of posterior chamber intraocular lens using a 30-gauge needle was performed. Patients were required to have at least 1 year of follow-up to be included in the analysis. Short-term data were collected 1 month after surgery, and long-term data were collected 1 year after surgery. Data collected included visual acuity, lens stability, intraocular pressure, and the development of complications.
RESULTS: Visual acuity improved from Snellen 20/309 preoperatively to Snellen 20/27 at postoperative Month 12 (P = 0.03). Short-term complications included increased intraocular pressure (n = 4) and corneal edema (n = 2). Long-term complications included exposed superior haptic (n = 1) and recurrent anterior chamber inflammation (n = 1).
CONCLUSION: The novel surgical technique for sutureless intrascleral fixation of a 3-piece intraocular lens is well tolerated 1 year after surgery.
METHODS: A retrospective chart review of a consecutive series of 9 eyes of 8 patients who underwent sutureless intrascleral fixation of posterior chamber intraocular lens using a 30-gauge needle was performed. Patients were required to have at least 1 year of follow-up to be included in the analysis. Short-term data were collected 1 month after surgery, and long-term data were collected 1 year after surgery. Data collected included visual acuity, lens stability, intraocular pressure, and the development of complications.
RESULTS: Visual acuity improved from Snellen 20/309 preoperatively to Snellen 20/27 at postoperative Month 12 (P = 0.03). Short-term complications included increased intraocular pressure (n = 4) and corneal edema (n = 2). Long-term complications included exposed superior haptic (n = 1) and recurrent anterior chamber inflammation (n = 1).
CONCLUSION: The novel surgical technique for sutureless intrascleral fixation of a 3-piece intraocular lens is well tolerated 1 year after surgery.