Descemet membrane endothelial keratoplasty and corneal biomechanics.

Hernández Esteban L, Orduña Domingo E

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To study the behaviour of the biomechanical properties of the cornea in DMEK (Descemet membrane endothelial keratoplasty).

METHOD: Prospective longitudinal observational study. 21 pre and post-DMEK eyes. 3-month follow-up with the dynamic Scheimpflug Analyzer (Corvis ST, Oculus; Wetzlar, Germany). The following parameters were measured: IOPnc: non-corrected intraocular pressure (IOP), IOPb: IOP corrected by biomechanics, maximum deflection amplitude (DefA), CCT: central corneal pachymetry, flattening speed 1 and 2, peak distance, HC deformation amplitude: deformation amplitude in maximum concavity, integrated inverse concave radius, DAR 1 and 2: deformation amplitude at 1mm and 2mm from the corneal apex, respectively. ARTh: Ambrosial pachymetric ratio, SP1: stiffness parameter, CBI: Corvis Biomechanical index and the maximum inverse radius. Pre-operative and post-operative measurements were performed with a 3-month follow-up and compared with a paired sample t-test.

RESULTS

There was a significant decrease in the IOPnc of 1.54±3mmHg (p<0.05), a significant increase in the post-surgical IOPb of 3.79±3.18mmHg (p<0.001), a significant pachymetric decrease of 164.4±91.35μm (p<0.001) after the intervention. All dynamic parameters of the Scheimpflug analyzer changed significantly after surgery (p<0.05), except the ARTh and IWC variables.

CONCLUSIONS

Variables indicate a decrease in corneal strength post-DMEK, with an increase in IOPb, at least the first 3 months after surgery. This finding is especially relevant in the follow-up of patients with coexisting glaucoma.

Для цитирования: Hernández Esteban L, Orduña Domingo E. Descemet membrane endothelial keratoplasty and corneal biomechanics.. Archivos de la Sociedad Espanola de Oftalmologia. 2020. DOI: 10.1016/j.oftal.2020.03.024.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.