MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2023/7680659

Медицинская библиотека · Journal of ophthalmology · 2023

Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation.

Gao Ruxin, Liu Jinkun, Zhou Xiaojie, Huang Luping, Huang Weiyi, Xue Yingying, Wang Fei, Gong Songjian, Wu Renyi, Wang Yuhong

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the influence of pilocarpine eyedrops on the ocular biometric parameters and whether these parameter changes affect the intraocular lens (IOL) power calculation in patients with primary angle-closure glaucoma (PACG).

METHODS

Twenty-two PACG patients and fifteen normal subjects were enrolled. Ocular biometric parameters including the axial length (AL), anterior chamber depth (ACD), lens thickness (LT), mean keratometry (Km), and white-to-white distance (WTW) were measured by using a Lenstar LS 900 device before and at least 30 minutes after instillation of 2% pilocarpine eyedrops. Lens position (LP) was calculated, and the IOL power prediction based on the ocular biometric parameters was performed using the Barrett Universal II, Haigis, Hoffer Q, Holladay I, or SRK/T formulas before and after pilocarpine application.

RESULTS

In both PACG and normal groups, pilocarpine eyedrops induced a slight but statistically significant increase in the mean AL (0.01 mm for both groups) and mean LT (0.02 mm and 0.03 mm, respectively) but a significant decrease in the mean ACD (0.03 mm and 0.05 mm, respectively) and mean LP (0.02 mm and 0.04 mm, respectively). No significant changes in the mean Km and WTW were noticed in both groups. In addition, the IOL power calculation revealed insignificant changes before and after the pilocarpine instillation in both groups, regardless of the formula used.

CONCLUSIONS

Pilocarpine eyedrops can induce slight changes in the ocular biometric parameters including the AL, ACD, LT, and LP. However, these parameter changes will not result in a significant difference in IOL power estimation.

Для цитирования: Gao Ruxin, Liu Jinkun, Zhou Xiaojie, Huang Luping, Huang Weiyi, Xue Yingying, Wang Fei, Gong Songjian, Wu Renyi, Wang Yuhong. Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation.. Journal of ophthalmology. 2023. DOI: 10.1155/2023/7680659.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.