MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10633-023-09949-4

Медицинская библиотека · Documenta ophthalmologica. Advances in ophthalmology · 2023

Objective detection of visual field defects with multifrequency VEPs.

Crux Katja, Huchzermeyer Cord, Kremers Jan, Horn Folkert K

СтатьяПеревод в очереди

Аннотация

PURPOSE: To correlate multifrequency pattern reversal VEPs in quadrants (QmfrVEPs) with perimetric field losses for objective detection of visual field losses.

METHODS

QmfrVEP measurements were performed using four LED-based checkerboard stimulators to stimulate the four quadrants of the visual field. QmfrVEPs were measured monocularly in 5 normal subjects and in 5 glaucoma patients who showed losses in conventional Octopus perimetry. The pattern reversal frequency varied slightly between the stimulators: (11.92, 12.00, 12.08 and 12.16 reversals/sec). The responses to the different stimuli were identified by discrete Fourier analysis. VEPs were recorded using different electrode configurations, and the recording with the highest signal-to-noise ratio (SNR) was used for further analysis.

RESULTS

QmfrVEP responses from the different quadrants can be reliably measured and separated using the 0.08 reversals/sec interstimulus reversal frequency differences. The signal-to-noise ratio in the four quadrants was significantly correlated with the equivalent visual field losses obtained with perimetry (Spearman rank correlation: P < 0.001). In the five glaucoma patients, the SNR was reduced in 15 out of the 16 quadrants with a perimetric defect, in comparison to the results in quadrants of healthy subjects. This confirms the sensitivity of the procedure.

CONCLUSION

QmfrVEP responses can be measured reliably. This pilot study suggests that high SNR values exclude visual field defects and that focal defects can be identified in glaucoma patients.

TRIAL REGISTRATION: www.

CLINICALTRIALS: gov . NCT00494923.

Для цитирования: Crux Katja, Huchzermeyer Cord, Kremers Jan, Horn Folkert K. Objective detection of visual field defects with multifrequency VEPs.. Documenta ophthalmologica. Advances in ophthalmology. 2023. DOI: 10.1007/s10633-023-09949-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.