m+Medelevator.RU
← Поиск публикаций
Neurosurgery · 2010

In-stent thrombosis and stenosis after neck-remodeling device-assisted coil embolization of intracranial aneurysms.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kanaan Hilal, Jankowitz Brian, Aleu Aitziber, Kostov Dean, Lin Ridwan, Lee Kimberly, Panipitiya Narendra, Gologorsky Yakov, Sandhu Emir, Rissman Lauren, Crago Elizabeth, Chang Yue-Fang, Kim Seong-Rim, Jovin Tudor, Horowitz Michael

Аннотация

BACKGROUND: Intrinsic thrombosis and stenosis are complications associated with the use of neck-remodeling devices in the treatment of intracranial aneurysms.

OBJECTIVE: To examine the technical and anatomic factors that predict short- and long-term stent patency.

METHODS: We undertook a retrospective review of 161 patients who underwent coil embolization of 168 ruptured and unruptured aneurysms assisted by the use of a neck-remodeling device. One hundred twenty-seven patients had catheter-based angiographic follow-up to evaluate 133 stent-coil constructs (mean, 15.4 months; median, 12.7 months). The technique of microcatheter jailing was used in a majority of patients; nonstandard stent configurations were also used.

RESULTS: Clinical follow-up for all patients who had catheter-based angiograms demonstrated that among 133 stent constructs, a total of 9 (6.8%) had an in-stent event: 6 acute or subacute thrombosis (4.5%) and 3 delayed stenosis or occlusion (2.3%). Seven of these constructs were associated with a symptomatic event (5.3%). A significantly higher rate of in-stent events was seen with the use of constructs to treat anterior communicating artery aneurysms. When all patients are considered, including those who did not receive catheter-based follow-up imaging, 2 of 168 procedures (1.2%) resulted in the death of a patient, and procedural morbidity was 14.9%.

CONCLUSION: From these results and those in the published literature, in-stent complication rates are low in carefully selected patients. The use of dual antiplatelet therapy, sensitivity assays, and glycoprotein IIb/IIIa inhibitors may decrease the rate of acute and chronic in-stent complications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты