m+Medelevator.RU
← Поиск публикаций
Medicine · 2026

Evaluation of clinical performance of artificial intelligence-assisted measurement of thoracic aortic diameter on non-contrast CT.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Suzuki Akiyoshi, Tomizawa Nobuo, Yamamoto Kotaro, Morita Yuichi, Fujita Shohei, Sano Katsuhiro, Akashi Toshiaki, Nishizawa Mitsuo, Suzuki Kazuhiro, Wada Akihiko, Endo Daisuke, Matsushita Satoshi, Kumamaru Kanako K, Funaki Keiichi, Sperl Jonathan, Tabata Minoru, Aoki Shigeki

Аннотация

This study aimed to evaluate the clinical performance of artificial intelligence (AI)-assisted measurement of thoracic aortic diameter on non-contrast computed tomography (NCCT). This single-center prospective study included 79 patients (mean age = 70 ± 13 standard deviation; 46 men) who underwent NCCT and arterial phase contrast-enhanced computed tomography (CECT) for evaluating aortic diseases between 2021 and 2022. Maximum diameters of 9 American Heart Association landmarks and the maximum ascending/descending aorta were measured. Upper limits of the 95% confidence interval (CI) for the absolute difference in aortic diameter between the AI-assisted/manual method on NCCT and the manual method on CECT (DiffAI-assisted/Diffmanual) were calculated and compared using a predefined cutoff of 1.5 mm. Evaluation times were also compared. No significant difference was found between per-patient DiffAI-assisted and Diffmanual (1.10 mm; 95% CI = 1.03-1.18 vs 1.03 mm; 95% CI = 0.95-1.11, P = .058); the upper limit of the 95% CI was <1.5 mm. The upper limit of the 95% CI of the geometric mean DiffAI-assisted and Diffmanual was also <1.5 mm at each landmark. The median evaluation time of the AI-assisted method was shorter than that of the manual method (expert radiologist = 272 seconds [interquartile range (IQR) = 229-313] vs 496 seconds [IQR = 438-550]; P < .001, training radiologist: 304 seconds [IQR = 257-404] vs 710 seconds [IQR = 563-855]; P < .001). AI-assisted thoracic aortic diameter measurement on NCCT was as accurate as manual measurement on CECT; its evaluation time was shorter than that of manual measurement on NCCT.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты