m+Medelevator.RU
← Поиск публикаций
Cardiovascular and interventional radiology · 2018

Custom-Made Endograft for Endovascular Repair of Thoraco-Abdominal Aneurysm and Type B Dissection: Single-Centre Experience.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lucatelli Pierleone, Cini Marco, Benvenuti Antonio, Saba Luca, Tommasino Giulio, Guaccio Giulia, Munneke Graham, Neri Eugenio, Ricci Carmelo

Аннотация

AIMS: To report a series of patients treated with the Jotec custom-made endograft for thoraco-abdominal aneurysms and dissections and identify predictive factors for re-intervention.

METHODS: We retrospectively analysed 49 patients unsuitable for surgery, treated between 2011 and 2017 (71.3 ± 9.5 years; 15 females). Indications included Crawford type 4 aneurysm in 25 patients, type 3 in 13, type 2 in 4, type 1 in 2 and chronic aneurysmal dilatation of the false lumen following dissection in 5 cases. Mean aneurysm diameter was 58.7 ± 8.4 mm. The study aims were to assess procedural success, complications rate, mortality and long-term follow-up. We also analysed factors that predicted the need for re-intervention.

RESULTS: The endograft was successfully deployed in all patients, catheterization of the fenestration and/or branches was achieved in 152/156 (97.4%) vessels. Early complications occurred in 10 patients (3 paraplegia, 3 haemorrhages, pancreatitis, aortic rupture, iliac artery rupture, 2 strokes). Thirty-day mortality was 10.2% and 180-day mortality 14.3%; two non procedure related deaths occurred. Mean follow-up was 23.6 ± 29.9 months [range 1-80]. No patients needed surgical explantation or developed significant renal impairment. Endoleak rate was 34.6% and re-intervention rate 9.7%. The aneurysm sac reduced or was stable in 36/49, and enlarged in 9/49 patients prompting re-intervention. Primary, primary-assisted and secondary patency of fenestrations/branches at 80 months was 90, 96 and 100%. Re-intervention was required more frequently in braches than in fenestrations, most commonly the external type branches.

CONCLUSIONS: The results of the Jotec endograft are comparable to other devices, with acceptable complication and re-intervention rates. Fenestration and inner-branch should be preferred due to lower re-intervention rates.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты