MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.autneu.2025.103332

Медицинская библиотека · Autonomic neuroscience : basic & clinical · 2025

Reduced resting beat-to-beat blood pressure variability in patients with Parkinson's disease.

Guerrero Rosa V D, Sabino-Carvalho Jeann L, Brandão Pedro R P, Neri Jhenny V, Vianna Lauro C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Parkinson's disease (PD) is a progressive neurodegenerative disorder that affects both motor and non-motor functions, including autonomic regulation. In the cardiovascular system, autonomic dysfunction may result in blood pressure (BP) abnormalities, such as altered variability. Therefore, the present study aimed to test the hypothesis that patients with PD exhibit increased resting beat-to-beat blood pressure variability (BPV) compared to healthy controls.

METHODS

Beat-to-beat heart rate (via electrocardiography) and BP (via photoplethysmography) were continuously recorded in 19 patients with PD, 15 age-matched older adults, and 19 young adults. Cardiac output (CO) and total peripheral resistance (TPR) were estimated using the ModelFlow method. BPV was assessed using several indices, including the standard deviation (SD) and average real variability (ARV).

RESULTS

Compared to both older and younger control groups, patients with PD exhibited lower ARV values for systolic (1.6 ± 0.5 vs. 2.3 ± 0.5 and 3.1 ± 1.1 mm Hg, P = 0.001), diastolic (0.9 ± 0.2 vs. 1.1 ± 0.4 and 1.5 ± 0.6 mm Hg, P = 0.001), and mean (0.9 ± 0.2 vs. 1.2 ± 0.4 and 1.5 ± 0.5 mm Hg, P = 0.001) BP. In addition, patients with PD showed reduced ARV in TPR compared to the older control group (0.5 ± 0.2 vs. 0.7 ± 0.7 mm Hg/L/min, P = 0.045). However, ARV in CO did not differ significantly between PD patients and older adults (119 ± 68 vs. 136 ± 48 mL/min, P = 0.806). Similar patterns were observed when using other BPV indices.

CONCLUSION

These findings suggest that Parkinson's disease may lead to a reduction in beat-to-beat blood pressure variability, potentially driven by changes in total peripheral resistance rather than cardiac output.

Для цитирования: Guerrero Rosa V D, Sabino-Carvalho Jeann L, Brandão Pedro R P, Neri Jhenny V, Vianna Lauro C. Reduced resting beat-to-beat blood pressure variability in patients with Parkinson's disease.. Autonomic neuroscience : basic & clinical. 2025. DOI: 10.1016/j.autneu.2025.103332.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.