Dento maxillo facial radiology · 2025
MR cisternography for trigeminal neuralgia: comparison between gradient-echo and spin echo 3D sequences.
СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wamasing Natnicha, Watanabe Hiroshi, Kuribayashi Ami, Imaizumi Akiko, Sakamoto Junichiro, Tomisato Hiroshi
Аннотация
OBJECTIVE: To quantitatively and qualitatively compare directly 2 types of cisternography images for diagnosing trigeminal neuralgia (TN) using 3-T MRI.
METHODS: This prospective study recruited 64 patients with a clinical diagnosis or suspicion of TN. Patients were examined through the three-dimensional Constructive Interference in Steady State (CISS) and Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) sequences. Three radiologists quantitatively measured the signal intensity of the trigeminal nerve (cranial nerve V, CN5) (SICN5), cerebrospinal fluid (CSF) (SICSF), and contrast between CN5 and CSF (Cont.). Additionally, 2 radiologists qualitatively evaluated the basilar artery (BA), CN5, CSF, image artefacts, and overall image quality. Statistical analyses included paired-sample t-tests, non-parametric McNemar tests, and the Friedman test (significance set at P < .05).
RESULTS: Mean SICN5 (P < .001), SICSF (P = .679), and Cont. (P < .001) were as follows: 203.08 ± 26.68, 936.03 ± 91, and 3.68 ± 0.74 in CISS; 46.80 ± 16.88, 940.61 ± 71.39, and 23.19 ± 14.52 in SPACE. Low-to-moderate CN5 and BA visibility was observed in all cases in CISS, while it was noted in one case for CN5 and in none for BA in SPACE (P < .001). Homogenous CSF and minor artefacts were observed in 14 cases in CISS, while it was seen in 52 cases for CN5 and 59 for BA in SPACE (P < .001). The overall image quality was scored as 4 in 57 cases in SPACE, while no cases received this score in CISS (P < .001).
CONCLUSIONS: Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions provided better images than CISS for evaluating CN5 and prepontine cistern vascularity, indicating a valuable sequence for TN diagnosis.
ADVANCES IN KNOWLEDGE: This study indicates that SPACE should be selected for TN diagnosis instead of CISS sequence.
METHODS: This prospective study recruited 64 patients with a clinical diagnosis or suspicion of TN. Patients were examined through the three-dimensional Constructive Interference in Steady State (CISS) and Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) sequences. Three radiologists quantitatively measured the signal intensity of the trigeminal nerve (cranial nerve V, CN5) (SICN5), cerebrospinal fluid (CSF) (SICSF), and contrast between CN5 and CSF (Cont.). Additionally, 2 radiologists qualitatively evaluated the basilar artery (BA), CN5, CSF, image artefacts, and overall image quality. Statistical analyses included paired-sample t-tests, non-parametric McNemar tests, and the Friedman test (significance set at P < .05).
RESULTS: Mean SICN5 (P < .001), SICSF (P = .679), and Cont. (P < .001) were as follows: 203.08 ± 26.68, 936.03 ± 91, and 3.68 ± 0.74 in CISS; 46.80 ± 16.88, 940.61 ± 71.39, and 23.19 ± 14.52 in SPACE. Low-to-moderate CN5 and BA visibility was observed in all cases in CISS, while it was noted in one case for CN5 and in none for BA in SPACE (P < .001). Homogenous CSF and minor artefacts were observed in 14 cases in CISS, while it was seen in 52 cases for CN5 and 59 for BA in SPACE (P < .001). The overall image quality was scored as 4 in 57 cases in SPACE, while no cases received this score in CISS (P < .001).
CONCLUSIONS: Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions provided better images than CISS for evaluating CN5 and prepontine cistern vascularity, indicating a valuable sequence for TN diagnosis.
ADVANCES IN KNOWLEDGE: This study indicates that SPACE should be selected for TN diagnosis instead of CISS sequence.