MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2003-44803

Медицинская библиотека · Zentralblatt fur Chirurgie · 2003

[Reconstruction of bile duct lesions by an autologous vein graft and a bio-degradable endoluminal stent in an animal model: technique and clinical impact].

Heistermann H P, Palmes D, Hierlemann H, Ebsen M, Horstmann R, Hohlbach G, Spiegel H U

Сравнительное исследованиеАннотация на английскомСтатьяПеревод в очереди

Аннотация

INTRODUCTION

In this study a new treatment of bile duct lesions was investigated. A segment of the bile duct was replaced by an autologous venous interponate which had been endoluminally stented with a braided bio-degradable stent.

METHODS

A total of 18 pigs (20-28 kg) was divided into three equal groups (I-III). In each group a 2 cm segment of the jugular vein was harvested. The animals in Group I (vein group, n = 6) underwent resection of a 2 cm long segment of the common bile duct which was replaced solely by the venous interponate, in Group II (stent group, n = 6) the venous interponate had been endoluminally stented by a braided bio-degradable stent. Group III (control group, n = 6) underwent only a circular mobilization of the common bile duct. Postoperatively survival rate, general condition as well as the weight were observed and checked for 6 months. During surgery and finally after sacrifice after 6 months blood and tissue samples were taken and semiquantitatively scored concerning grade of inflammation and fibrosis.

RESULTS

In the stent and control group all animals survived in good condition. 3 pigs of the vein group died within 3 weeks showing signs of biliary peritonitis, another one died due to a high grade stenosis of the common bile duct with secondary biliary cirrhosis after 4 months. In the stent group all animals survived until sacrifice after 6 months. On examination the venous interponate was laminated with bile duct epithelium showing the diameter of the implanted stent.

CONCLUSION

The reconstruction of bile duct lesions by a venous interponate in combination with a bio-degradable stent is easy to perform and represents a clinically interesting alternative to the biliodigestive anastomosis because of the preservation of the sphincter oddi. After 6 months the stent is completely absorbed and the venous interponate is laminated with bile duct epithelium.

Для цитирования: Heistermann H P, Palmes D, Hierlemann H, Ebsen M, Horstmann R, Hohlbach G, Spiegel H U. [Reconstruction of bile duct lesions by an autologous vein graft and a bio-degradable endoluminal stent in an animal model: technique and clinical impact].. Zentralblatt fur Chirurgie. 2003. DOI: 10.1055/s-2003-44803.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.