DOI 10.1007/s10792-025-03684-2

Медицинская библиотека · International ophthalmology · 2025

Accuracy of eight intraocular lens power calculation formulas in patients with ciliary sulcus implantation.

Xu Pusheng, Zhang Xinyu, Lian Zhangkai, Liu Zhenzhen, Young Charlotte Aimee, Liu Siyuan, Zheng Danying, Jin Guangming

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the accuracy of intraocular lens (IOL) power calculation for ciliary sulcus-implanted IOL.

METHODS

Patients with IOL (Tecnis ZA9003) implanted in the ciliary sulcus were reviewed from March 1, 2021 to November 1, 2024 at Zhongshan Ophthalmic Center, Guangzhou, China. Optic capture was used at all case. The prediction error (PE) and mean absolute error (MAE) of eight new and old formulas including Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), Haigis, Hoffer QST, Holladay 1, Kane, Radial Basis Function 3.0 (RBF 3.0), and SRK/T formula were compared. The second-generation Wang-Koch adjustment (WK2) for axial length (AL) > 26.5 mm and adjusted surgeon factor for IOL implanted in the ciliary sulcus (SF_cs) were used to modify Holladay 1 formula.

RESULTS

56 eyes from 56 patients were enrolled. The performance of each formula ranked by mean PE from lowest to highest were Holladay 1 (- 0.42 D), BUII (- 0.47 D), EVO (- 0.49 D), Haigis (- 0.49 D), RBF 3.0 (- 0.52 D), SRK/T (- 0.53 D), Kane (- 0.56 D), and Hoffer QST (- 0.58 D). BUII formula reached the lowest MAE (0.68 D), while Hoffer QST and Kane formula had the highest MAE (0.75 D). Holladay 1, modified with WK2 and a SF_sc of 1.37, achieved a mean PE of 0 ± 0.67 D, the lowest MAE (0.52) and MedAE (0.40), as well as the highest percentage of eyes with PE within ± 0.25 D, ± 0.50 D, and ± 1.00 D.

CONCLUSION

Among the eight included formulas, Holladay 1 formula modified with WK2 adjustment and a SF_cs of 1.37 was recommended for patients with sulcus-implanted optic-captured ZA9003 IOL.

Для цитирования: Xu Pusheng, Zhang Xinyu, Lian Zhangkai, Liu Zhenzhen, Young Charlotte Aimee, Liu Siyuan, Zheng Danying, Jin Guangming. Accuracy of eight intraocular lens power calculation formulas in patients with ciliary sulcus implantation.. International ophthalmology. 2025. DOI: 10.1007/s10792-025-03684-2.