Prospective randomized comparison of a steerable versus a non-steerable sheath for typical atrial flutter ablation.

Сравнительное исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Matsuo Seiichiro, Yamane Teiichi, Tokuda Michifumi, Date Taro, Hioki Mika, Narui Ryohsuke, Ito Keiichi, Yamashita Seigo, Hama Yoshiyuki, Nakane Tokiko, Inada Keiichi, Shibayama Kenri, Miyanaga Satoru, Yoshida Hiroshi, Miyazaki Hidekazu, Abe Kunihiko, Sugimoto Ken-ichi, Taniguchi Ikuo, Yoshimura Michihiro

Аннотация

AIMS: Although cavotricuspid isthmus (CTI) ablation can cure typical atrial flutter (AFL), it might be difficult to achieve a bidirectional conduction block in the isthmus in some patients. We investigated the usefulness of a steerable sheath for CTI ablation in patients with typical AFL or atrial fibrillation.

METHODS AND RESULTS: A total of 40 consecutive patients (36 males; mean age 55.2 +/- 10.0 years) undergoing CTI ablation were randomized to one of the following two groups: group S (using a steerable long sheath) or group NS (using a non-steerable long sheath). Ablation was performed using an 8 mm tip catheter. The anatomy of the CTI was evaluated by a dual-source computed tomography scan prior to the procedure. The procedural endpoint was the achievement of a bidirectional isthmus conduction block. Bidirectional block in the CTI was achieved in all patients with 485.3 +/- 416.4 s of radiofrequency (RF) application. The CTI anatomy, including the length, depth, and morphology, was similar between the two groups. The duration and total amount of RF energy delivery were significantly shorter and smaller in group S than in group NS (310 +/- 193 vs. 661 +/- 504 s, P = 0.006, and 12,197 +/- 7306 vs. 26,906 +/- 21,238 J, P = 0.006, respectively).

CONCLUSION: The use of a steerable sheath reduced the time and amount of energy needed to achieve a bidirectional conduction block in the CTI. For patients in whom the establishment of a conduction block is difficult, a steerable sheath should be considered as a therapeutic option for typical AFL ablation.