m+Medelevator.RU
← Поиск публикаций
Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2002

Sensitivity of photoscreening to detect high-magnitude amblyogenic factors.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Donahue Sean P, Johnson Tammy M, Ottar Wanda, Scott William E

Аннотация

PURPOSE: To determine the sensitivity of a unique pupil-size based set of referral criteria of the MTI PhotoScreener(Medical Technology and Innovations, Inc, Cedar Falls, Iowa) to detect high magnitude refractive error.

METHODS: The photoscreening photographs of 949 preschool children previously analyzed were reevaluated with the new referral criteria. The original photographs had been obtained from pediatricians' offices and public health and Women, Infants, and Children's (WIC) clinics. The results of this analysis were compared with the gold standard clinical examination and cycloplegic refraction. Sensitivities were calculated for amblyogenic factors based on the magnitude of the refractive error.

RESULTS: For 26 patients with anisometropia, the sensitivity to detect anisometropia increased from 46% for +1.25 or greater spherical interocular difference to 100% for +2.50 spherical intraocular difference. For 36 patients with hypermetropia in at least 1 meridian ranging from +3.75 to +7.50 D, sensitivity increased from 53% to detect +3.75 D or greater to 70% for +5.00 D or greater. The sensitivity to detect hypermetropia of +5.75 D or greater was 100%. These criteria detected 82% of patients with astigmatism greater than or equal to +3.00 D, and 100% of patients with astigmatism greater than +3.50 D.

CONCLUSION: It is crucial that screening programs avoid over-referrals caused by high false-positive screening rates. The sensitivity of our new criteria increases with higher magnitude refractive error; patients with moderate and severe amblyogenic factors are almost never missed. While the sensitivity to detect lower magnitude refractive error is poor, the amblyogenic impact of such errors remains to be determined.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты