m+Medelevator.RU
← Поиск публикаций
Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2018

Upper Airway Stimulation for Obstructive Sleep Apnea: 5-Year Outcomes.

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Woodson B Tucker, Strohl Kingman P, Soose Ryan J, Gillespie M Boyd, Maurer Joachim T, de Vries Nico, Padhya Tapan A, Badr M Safwan, Lin Ho-Sheng, Vanderveken Olivier M, Mickelson Sam, Strollo Patrick J

Аннотация

Objective To present 5-year outcomes from a prospective cohort of patients with obstructive sleep apnea (OSA) who were treated with upper airway stimulation (UAS) via a unilateral hypoglossal nerve implant. Study Design A multicenter prospective cohort study. Setting Industry-supported multicenter academic and clinical trial. Methods From a cohort of 126 patients, 97 completed protocol, and 71 consented to a voluntary polysomnogram. Those having continuous positive airway pressure failure with moderate to severe OSA, body mass index <32 kg/m2, and no unfavorable collapse on drug-induced sleep endoscopy were enrolled in a phase 3 trial. Prospective outcomes included apnea-hypopnea index (AHI), oxygen desaturation index, and adverse events, as well as measures of sleepiness, quality of life, and snoring. Results Patients who did and did not complete the protocol differed in baseline AHI, oxygen desaturation index, and Functional Outcomes of Sleep Questionnaire scores but not in any other demographics or treatment response measures. Improvement in sleepiness (Epworth Sleepiness Scale) and quality of life was observed, with normalization of scores increasing from 33% to 78% and 15% to 67%, respectively. AHI response rate (AHI <20 events per hour and >50% reduction) was 75% (n = 71). When a last observation carried forward analysis was applied, the responder rate was 63% at 5 years. Serious device-related events all related to lead/device adjustments were reported in 6% of patients. Conclusions Improvements in sleepiness, quality of life, and respiratory outcomes are observed with 5 years of UAS. Serious adverse events are uncommon. UAS is a nonanatomic surgical treatment with long-term benefit for individuals with moderate to severe OSA who have failed nasal continuous positive airway pressure.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты