m+Medelevator.RU
← Поиск публикаций
Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2015

The use of anatomically drop-shaped bioactive glass S53P4 implants in the reconstruction of orbital floor fractures--A prospective long-term follow-up study.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Stoor P, Mesimäki Karri, Lindqvist Christian, Kontio Risto

Аннотация

An isolated fracture of the orbital floor needs reconstruction if there is a clear herniation of adipose tissue or of the rectus inferior muscle into the maxillary sinus. A prospective study was carried out treating 20 patients with an isolated blow-out fracture of the orbital floor or with a combined zygomatico-orbito-maxillary complex fracture, using a newly designed anatomically drop-shaped implants made of bioactive glass (BAG) S53P4. Computed tomography (CT) was performed immediately postoperatively to confirm the correct position of the plate. The patients were followed up for an average of 32 months clinically and radiologically with magnetic resonance imaging (MRI) for an average of 31 months. None of the patients had any signs of complications related to the implant and the clinical outcome was very good. None of the patients had persisting diplopia. The level of the pupillas was normal in 15 of 20 patients. Minor hypo-ophthalmos ranging from 0.5 to 1.0 mm was observed in three patients, and moderate hypo-ophthalmos of 2.0 mm was seen in one patient. Hyperophthalmos of 1.0 mm was seen in one patient. Minor enophthalmos on the operated side ranging from 0.5 to 1.0 mm was seen in eight patients. Mild to moderate paraesthesia of the infraorbital nerve was observed in six patients. The immediate postoperative CT and the long term follow-up MRI revealed that the drop-shaped BAG implants retained their correct position in the orbital floor and did not show any evidence of losing their original shape or material resorption. No adverse tissue reaction was associated with the material. Due to the anatomical drop shape, the implants could successfully maintain the orbital volume and compensate for the retrobulbar adipose tissue atrophy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты