MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0021-9673(96)00244-0

Медицинская библиотека · Journal of chromatography. A · 1996

Screening and identification of familial defective apolipoprotein B-100 in clinical samples by capillary gel electrophoresis.

Lehmann R, Koch M, Pfohl M, Voelter W, Häring H U, Liebich H M

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

Familial defective apolipoprotein B-100 (FDB) is a dominantly inherited disorder. It is characterized by a decreased affinity of low density lipoprotein (LDL) for the LDL receptor, as a consequence of a substitution of adenine by guanine in exon 26 of the apolipoprotein B-100 gene, coding for the putative LDL receptor-binding domain of the mature protein. This disorder is associated with a strikingly high incidence of arteriosclerosis and tends to cause disease and premature death. In this communication we describe a rapid capillary gel electrophoretic method in combination with molecular biology techniques to facilitate the diagnosis of FDB. Mutation screening for FDB is performed by an allele-specific amplification followed by capillary gel electrophoresis (CGE). For the combined polymerase chain reaction (PCR)-CGE method, a total analysis time of only 3 h is needed, a period that is normally necessary for the run and for staining of the gel only, not including the time for PCR, gel casting, etc. In our pilot study 4 of 43 hypercholesterolemic patients were found to have the predominant apoB 3500 codon mutation. The verification is demonstrated by DNA-sequencing. This pilot study will be followed by a large cohort analysis of the south-west German population to determine the frequency of FDB in this area. The PCR-CGE method on the Dionex capillary electrophoresis system (CES I) allows rapid, fully automated detection of the mutation resulting in the unequivocal diagnosis of FDB.

Для цитирования: Lehmann R, Koch M, Pfohl M, Voelter W, Häring H U, Liebich H M. Screening and identification of familial defective apolipoprotein B-100 in clinical samples by capillary gel electrophoresis.. Journal of chromatography. A. 1996. DOI: 10.1016/0021-9673(96)00244-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.