m+Medelevator.RU
← Поиск публикаций
The Annals of thoracic surgery · 2022

Evolution of Pulmonary Valve Management During Repair of Tetralogy of Fallot: A 14-year Experience.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Schulte Linda J, Miller Paighton C, Bhat Amrita N, Carvajal-Dominguez Horacio G, Chomat Michael R, Miller Jacob R, Nath Dilip, Eghtesady Pirooz

Аннотация

BACKGROUND: The optimal repair strategy for tetralogy of Fallot remains controversial. This report presents a 14-year evolution of management of the pulmonary valve (PV) from transannular patch to valve-sparing repair to neovalve creation using living right atrial appendage tissue.

METHODS: A retrospective review of 172 consecutive patients undergoing complete repair for TOF between January 2007 and June 2021 was performed. Clinical and follow-up data were analyzed by repair group. Neopulmonary valve (NPV) creation using right atrial appendage tissue was introduced in 2019. Failure of valve-sparing repair was defined as needing reintervention for recurrent right ventricular outflow tract obstruction (RVOTO).

RESULTS: Median age and weight at repair were 4.9 months and 6 kg, respectively. Median preoperative PV size and z-score were 6.4 mm (5.2-8.3 mm) and -3.2 (-4.1 to -2.1), respectively. Patients who underwent valve-sparing repair had larger PV size and z-score compared with patients who underwent transannular patch procedures (8 mm vs 5.6 mm; -2.1 vs -3.2; both P < .001). There were no hospital mortalities. Overall follow-up was 44 months. At last follow-up, 10% of patients who underwent valve-sparing repair had repeat intervention for recurrent RVOTO. Patients who had failed valve-sparing repair had significantly lower PV z-scores (-2.6 vs -1.9; P = .01). An NPV was used in 8 patients with a median PV z-score of -4 (-4.7 to -3.9). At 6 months, 6 patients (75%) had mild or trivial pulmonary insufficiency after NPV placement.

CONCLUSIONS: Repair of tetralogy of Fallot is a safe operation with excellent outcomes. Valve-sparing repair avoids right ventricular dilation but may fail for RVOTO at a PV z-score <-2. NPV creation offers an alternative option in patients with a small PV.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты