MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14309/ajg.0000000000002975

Медицинская библиотека · The American journal of gastroenterology · 2024

Linear-Array Endoscopic Ultrasound and Narrow-Band Imaging Measure the Invasion Depth of Nonpedunculated Rectal Lesions With Comparable Accuracy Based on a Randomized Controlled Trial.

Li Lingzhi, He Jiaming, Hu Haiyan, Wang Yingying, Li Weixin, Huang Shaohui, Rownoak Jahan, Xu Shenglin, Xie Fang, Wang Junfen, Mi Wenting, Cai Jianqun, Ye Yaping, Liu Side, Wang Jing, Li Yue

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

Linear-array endoscopic ultrasound (EUS) and narrow-band imaging (NBI) are both used to estimate the invasion depth of nonpedunculated rectal lesions (NPRLs). However, it is unclear which procedure is more accurate. This randomized controlled trial aimed to compare the diagnostic accuracy of linear EUS and NBI for estimating the invasion depth of NPRLs.

METHODS

This study is a single-center, randomized, tandem trial. Eligible patients with NPRLs were randomly assigned to A group (assessment with EUS followed by NBI) or B group (assessment with NBI followed by EUS). The invasion depth of each lesion was independently measured by each procedure and categorized as mucosal to slight submucosal (M-SM s , invasion depth <1,000 μm) or deep submucosal (SM d , invasion depth ≥1,000 μm) invasion, with postoperative pathology as the standard of measurement. The primary outcome was diagnostic accuracy, and secondary outcomes included sensitivity, specificity, and procedure time.

RESULTS

Eighty-six patients with NPRLs were enrolled, and 79 patients were finally analyzed, including 39 cases in the A group and 40 cases in the B group. Comparable diagnostic accuracies were observed between EUS and NBI (96.2% vs 93.7%, P = 0.625). EUS identified lesions with deep submucosal invasion with 81.8% sensitivity while that of NBI was 63.6% ( P = 0.500). The specificity of both EUS and NBI was 98.5%. The procedure time was also similar between EUS and NBI (5.90 ± 3.44 vs 6.4 ± 3.94 minutes, P = 0.450). Furthermore, the combined use of EUS and NBI did not improve diagnostic accuracy compared with EUS or NBI alone (94.9% vs 96.2% vs 93.7%, P = 0.333).

DISCUSSION: Linear EUS and NBI measure the invasion depth of NPRLs with comparable accuracy. The combination of the 2 methods does not improve the diagnostic accuracy. Single NBI should be preferred, considering its simplicity and convenience in clinical practice.

Для цитирования: Li Lingzhi, He Jiaming, Hu Haiyan, Wang Yingying, Li Weixin, Huang Shaohui, Rownoak Jahan, Xu Shenglin, Xie Fang, Wang Junfen, Mi Wenting, Cai Jianqun, Ye Yaping, Liu Side, Wang Jing, Li Yue. Linear-Array Endoscopic Ultrasound and Narrow-Band Imaging Measure the Invasion Depth of Nonpedunculated Rectal Lesions With Comparable Accuracy Based on a Randomized Controlled Trial.. The American journal of gastroenterology. 2024. DOI: 10.14309/ajg.0000000000002975.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.