m+Medelevator.RU
← Поиск публикаций
International urology and nephrology · 2026

Magnetic resonance urethrography-derived geometric parameters and their association with surgical complexity in pelvic fracture urethral injury repair.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bhusal Ishory, Jain Siddharth, Gupta Mehul, Chandola Stuti, Sharma Sanjay, Seth Amlesh, Nayyar Rishi, Kumar Manoj, Kumar Sanjay

Аннотация

BACKGROUND: Accurate preoperative planning is vital for successful surgical repair of pelvic fracture urethral injuries (PFUI). Magnetic resonance urethrography (MRU) offers a more detailed anatomical assessment of the posterior urethra than conventional urethrography. This study evaluates the role of MRU in PFUI repairs.

METHODS: This was a prospective, single-center observational study conducted at a tertiary academic institution between August 2022 and December 2024, aimed at correlating the surgical complexity of PFUI repairs with preoperative geometric parameters derived from MRU and conventional urethrography. Male patients aged ≥ 18 years diagnosed with PFUI were included.

RESULTS: Twenty male patients were studied, with a median age of 26 years (IQR: 20.5-36). The bulbomembranous urethra was the most frequent site of disruption (80%). Mean urethral gap measured 2.68 cm (SD 1.13) on MRU and 3.09 cm (SD 1.19) on conventional urethrography. Thirteen patients (65%) underwent non-pubectomy urethroplasty (NPU), and 7 underwent urethroplasty with pubectomy (PU). Within the NPU group, urethral mobilization sufficed in five, while eight required additional corporal separation. On MRU, mean distraction defect was significantly greater in the PU group (3.55 vs 2.22 cm in the NPU group, p < 0.01). Both MRU and conventional urethrography performed well on concordance analysis against the true gap length, with concordance correlation coefficients of 0.969 and 0.894 respectively.

CONCLUSION: Magnetic resonance urethrography (MRU) provides a more comprehensive and precise preoperative evaluation of PFUI compared to conventional urethrography, offering better visualization of the prostatic urethra, accurate gap measurement along with assessment of periurethral anatomic relationships.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты