m+Medelevator.RU
← Поиск публикаций
Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2020

First performance report of QIAreach™ Anti-SARS-CoV-2 Total Test, an innovative nanoparticle fluorescence digital detection platform.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Stieber Francis, Howard Jenny, Rao Sonia N, Kawamura L Masae, Manissero Davide, Love Joanna, Yang Mei, Uchiyama Robin, Parsons Sean, Miller Chris, Douwes Harmony, McDonald Aaron, Fairburn Luke, Boyle Jeffrey

Аннотация

In 2019, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) caused a global pandemic. Disease diagnosis, appropriate clinical management and infection control are all important factors in controlling the spread of SARS-CoV-2. The QIAreach™ Anti-SARS-CoV-2 Total Test (Anti-CoV2) is a rapid, qualitative serological test, using proprietary nanoparticle fluorescence technology to detect total antibody (IgA, IgM, and IgG) against SARS-CoV-2. Here we report the results of the US Food and Drug Administration (FDA) clinical agreement study. Thirty positive plasma or serum samples were taken from consenting individuals with polymerase chain reaction (PCR)-confirmed SARS-CoV-2 infection ≥14 days from symptom onset. Seventy-five samples from before the believed circulation of SARS-CoV-2 (November 1, 2019) were used to assess specificity. Positive percent agreement (PPA) and negative percent agreement (NPA) were calculated along with the corresponding exact two-sided 95 % confidence intervals (CI) using an FDA Emergency Use Authorized PCR test as the reference method. Anti-CoV2 was shown to have 100 % sensitivity (PPA; 95 % CI 88.4-100 %) and 100 % specificity (NPA; 95 % CI 95.2-100 %). Against 157 pre-pandemic samples, no cross-reactivity was observed with seasonal coronaviruses or other respiratory pathogens tested. Additionally, no interference was observed when samples were spiked with: conjugated bilirubin 0.4 mg/ml; unconjugated bilirubin 0.4 mg/ml; hemoglobin 5 mg/ml; prednisolone 0.12 mg/ml; triglycerides 15 mg/ml. In conclusion, Anti-CoV2 provides accurate qualitative detection of total antibodies against SARS-CoV-2.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты