Automated Computerized-based Intervention to Identify Hypomagnesemia in Primary Care Patients With Arrhythmia.

López-Garrigós Maite, Ahumada Miguel, Leiva-Salinas María, Blasco Alvaro, Flores Emilio, Leiva-Salinas Carlos, PRIMary Care-LABoratory (PRIMLAB) working group

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Hypomagnesemia early diagnosis and consequently early, timely magnesium supplementation is of utmost benefit, but it often goes underdiagnosed. The objective was to show and monitor an intervention to identify hypomagnesemia in patients with arrhythmia.

METHODS

A cross-sectional study was designed in the laboratory. In primary care patients, the Laboratory Information System would automatically add a serum magnesium test when sample availability is present in any request when a diagnosis of arrhythmia is made. We counted the number of detected patients with hypomagnesemia (serum magnesium <1.7 mg/dL, <0.7 mmol/L), and calculated the cost in reagent of each identified case.

RESULTS

In 430 patients with arrhythmia, serum magnesium was measured, and 41 (9.5%) had hypomagnesemia results. One patient showed severe hypomagnesemia values (<1.2 mg/dL and <0.49 mmol/L). Patients with a deficit were significantly ( P <0.01) older than the total group of patients with normal magnesium values (66.3±13.2 versus 61.6±12.5). Each case represented a cost of 3.15€ in reagent.

CONCLUSIONS

The automated computer-based intervention to identify patients with hypomagnesemia was useful and affordable, given the cost per detected case.

Для цитирования: López-Garrigós Maite, Ahumada Miguel, Leiva-Salinas María, Blasco Alvaro, Flores Emilio, Leiva-Salinas Carlos, PRIMary Care-LABoratory (PRIMLAB) working group. Automated Computerized-based Intervention to Identify Hypomagnesemia in Primary Care Patients With Arrhythmia.. Journal of patient safety. 2024. DOI: 10.1097/pts.0000000000001308.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.