BACKGROUND

The Drivewire 24 (DW24) is a newly FDA-cleared 0.024 inch steerable guidewire. Its proximally controlled deflectable tip allows for intravascular steering to facilitate selective navigation of diagnostic or therapeutic catheters. We present the first clinical experience with the DW24.

METHODS

All neurointerventional procedures using the DW24 from October 2024 to April 2025 were retrospectively reviewed. Indications, procedural details, DW24 performance, wire-related complications, and operator feedback were assessed.

RESULTS

27 procedures were performed utilizing the DW24. Indications included aneurysm (n=16), stroke (n=5), arteriovenous fistula or malformation (n=4), and diagnostic venography (n=2). Technical success was achieved in 92.6% of cases. Target vessels included the MCA, anterior cerebral artery, posterior cerebral artery, internal carotid artery segments, transverse sinus, and torcula. The device's radiopaque, hydrophilic distal tip aided fluoroscopic visibility, and the variable support enabled articulation across a range of aspiration and delivery catheters without requiring additional support devices. The DW24's steerability enabled access to challenging cerebrovascular anatomy, including one stroke case where conventional guidewires failed to reach a distal M2 occlusion. The DW24's intravascular steering also allowed for the delivery of catheters for Pipeline Embolization Device (PED) deployment and facilitated PED post-processing to improve wall apposition without requiring wire removal, reshaping, or balloon angioplasty. Operators observed a short learning curve. There were no device-related complications, though the wire's response to rotational force was a limitation.

CONCLUSION

The DW24 demonstrated a high technical success rate with no device-related complications. Its versatility across catheter sizes and precise controllability facilitate navigating complex cerebrovasculature. Further studies should assess efficacy in larger cohorts across additional clinical scenarios.

Для цитирования: Grin Eric Alexander, Sharashidze Vera, Chung Charlotte, Baranoski Jacob F, Rutledge Caleb, Riina Howard A, Shapiro Maksim, Raz Eytan, Nossek Erez. Early experience with the Drivewire 24: a newly FDA-approved steerable microwire.. Journal of neurointerventional surgery. 2026. DOI: 10.1136/jnis-2025-023730.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.