BACKGROUND

Digital self-monitoring applications could provide individuals with macular disease with a convenient, quantitative method for tracking metamorphopsia at home; yet the usability of such tools remains to be fully established.

OBJECTIVE

This study evaluated the usability of a macular quantitative square grid self-examination application, a semiquantitative, touch-based self-monitoring application for macular function.

METHODS

This study used a convergent mixed methods design. The application quantifies (1) distortion severity, (2) distortion area, and (3) temporal trends through a 3-step touch interface. A total of 24 adults with neovascular age-related macular degeneration or diabetic macular edema, accompanied by self-reported metamorphopsia, participated in a single supervised test session. A 10-item System Usability Scale (SUS) was used to assess usability, and semistructured interviews were conducted to gather further insights. Quantitative data were summarized descriptively, and qualitative feedback underwent inductive thematic analysis.

RESULTS

A total of 24 participants completed the GridMacuScan application self-assessment, the SUS questionnaire, and 11 participants completed the interview when data saturation was achieved. All eyes that showed distortion on the Amsler grid also produced positive distortion maps on the GridMacuScan application, yielding 100% diagnostic concordance. The mean SUS score was 82.1 (SD 8.7), indicating "good-excellent" usability. The inductive thematic analysis yielded four overarching themes: (1) high usability and positive overall experience, (2) perceived functional advantages, (3) shortcomings and optimization suggestions, and (4) strong willingness for continued use.

CONCLUSIONS

The GridMacuScan application demonstrated diagnostic sensitivity comparable to that of the traditional Amsler grid and received high user ratings for usability. Furthermore, it provided quantitative distortion metrics that could facilitate longitudinal disease surveillance. Future research must be conducted to validate performance in unsupervised home environments and investigate whether sustained use improves time-to-disease-progression detection and treatment outcomes.

Для цитирования: Li Shu, Zhang Enming, Pan Jiani, Xu Yan, Zheng Kairong, Xu Xun, Fang Qiong. Usability Evaluation of a Macular Quantitative Square Grid Self-Examination Application in Patients With Macular Disease: Mixed Methods Study.. JMIR human factors. 2026. DOI: 10.2196/79699.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.