npj biomedical innovations · 2026
An integrated digital-to-surgical framework for patient-specific chest wall resection and reconstruction using 3D-printed titanium implants: proof-of-concept study.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Goldsmith Ira, Bragg Thomas, Jayakumar Aravindh, Evans Peter Llewelyn
Аннотация
Patient-specific skeletal reconstruction of the chest wall following extensive resections that result in large, anatomically complex defects remains challenging using conventional reconstructive techniques. We describe an end-to-end digital-to-surgical workflow framework for patient-specific chest wall resection and reconstruction using three-dimensional (3D) printed titanium implants. The four-stage workflow integrates Computed Tomography (CT) imaging data, virtual 3D anatomical modelling, virtual tumour-margin planning, computer-aided implant design (CAD), stereolithographic prototype validation, and additive manufacturing using laser-powder bed fusion (L-PBF). High-resolution CT data in Digital Imaging and Communications in Medicine (DICOM) format were converted into patient-specific 3D-rendered models of the chest wall and tumour to enable virtual delineation of tumour extent and digitally planned resection margins. These digital resection models were then used to design anatomically matched patient-specific implants. Implant designs were validated using stereolithographic prototypes before definitive manufacture in titanium alloy. The workflow underwent clinical feasibility evaluation in six consecutive patients requiring major chest wall resection and reconstruction. Across all cases, digitally planned resections and reconstructions were performed without intraoperative modification. The implants demonstrated accurate anatomical fit, secure fixation, and satisfactory restoration of chest wall anatomy. During the available follow-up period ranging from 5 months to 5 years, no implant failures or implant-related complications were observed. Two patients who underwent reconstruction for palliation subsequently died from progression of their underlying disease. This proof-of-concept single-centre study demonstrates the clinical feasibility of a digital-to-surgical workflow and provides a foundation for future multicentre evaluation.