MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmii.2025.06.006

Медицинская библиотека · Journal of microbiology, immunology, and infection = Wei mian yu gan ran za zhi · 2025

An immunochromatographic device to detect antibodies for rapid diagnosis of human angiostrongyliasis in whole-blood and cerebrospinal fluid samples.

Boonroumkaew Patcharaporn, Sadaow Lakkhana, Kanchanangkul Nongnapas, Rodpai Rutchanee, Sanpool Oranuch, Intapan Pewpan M, Blair David, Maleewong Wanchai

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Human angiostrongyliasis is caused by the rat lung worm, Angiostrongylus cantonensis and is often a cause of eosinophilic meningitis (EOM) or meningoencephalitis. Humans are infected by consuming infective larvae from intermediate hosts (snails and slugs), paratenic hosts or contaminated vegetables. Here, a simple and rapid antibody-detection lateral-flow immunochromatographic test (ICT) was developed as a point-of-care tool for supporting diagnosis of human angiostrongyliasis. We also tested the ICT with cerebrospinal fluid (CSF) samples.

METHODS

We evaluated a new ICT format using a recombinant A. cantonensis galectin-2 (rAcGal2) protein as a target for anti-A. cantonensis IgG antibodies in simulated whole-blood samples (WBSs) and compared results with those obtained using corresponding serum samples.

RESULTS

The sensitivity and specificity values for IgG antibody detection in simulated WBSs were 82.0 (95 % CI 73.1-89.0) and 97.1 (95 % CI 93.3-99.0), while in serum samples these were 92.0 (95 % CI 84.8-96.5), and 97.1 (95 % CI 93.3-99.0), respectively. Results between simulated WBSs and serum samples did not differ significantly with a concordance of 96.3 % (Cohen's kappa 0.9177). Anti-Angiostrongylus antibodies were also detected in CSF samples: 12 out of 16 EOM cases were positive while all 10 CSF samples from control cases were negative.

CONCLUSION

The ICT is easy to implement and can provide supportive diagnosis at the bedside or in local and remote hospitals with limited facilities. An additional benefit is that it can be used with CSF samples obtained by lumbar puncture for management of high intracranial pressure of EOM patients in intensive care units.

Для цитирования: Boonroumkaew Patcharaporn, Sadaow Lakkhana, Kanchanangkul Nongnapas, Rodpai Rutchanee, Sanpool Oranuch, Intapan Pewpan M, Blair David, Maleewong Wanchai. An immunochromatographic device to detect antibodies for rapid diagnosis of human angiostrongyliasis in whole-blood and cerebrospinal fluid samples.. Journal of microbiology, immunology, and infection = Wei mian yu gan ran za zhi. 2025. DOI: 10.1016/j.jmii.2025.06.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.