Cardiology journal · 2026
Impact of iron deficiency on left ventricular noninvasive myocardial work indices in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Błaszkiewicz Michał J, Witkowski Tomasz G, Bombała Wojciech, Kosowski Michał, Kübler Piotr, Reczuch Krzysztof, Aleksandrowicz Krzysztof, Jankowska Ewa A, Protasiewicz Marcin
Аннотация
BACKGROUND: Aortic stenosis (AS) increases left ventricular (LV) afterload and systolic pressure (LVSP). Left ventricular myocardial work (LVMW) enables early detection of LV dysfunction. Recent evidence suggests that ID may reduce LVMW parameters, raising the question of whether ID further impairs LV systolic performance in patients with AS undergoing transcatheter aortic valve implantation (TAVI).
METHODS: We evaluated 100 patients with severe AS scheduled for TAVI between March 2021 and November 2022. All underwent ID screening according to the classic and novel ID definitions and echocardiographic assessment of LVMW before TAVI and at the 1-year follow-up.
RESULTS: Elimination of AS was observed within the 1-year follow-up in the whole population. Despite stable ejection fraction (EF) and global longitudinal strain (GLS), LVMW indices such as global work index (GWI) and global constructive work (GCW) significantly decreased from baseline in the entire population. However, when comparing ID and non-ID patients after the procedure, a statistically significant decrease in GWI and GCW was noted at the 1-year follow-up only in the TSAT > 20% group, not in the TSAT < 20% group. We also noted a significant correlation between TSAT status and echocardiographic as well as LVMW indices. When the classic ID definition was used, all LVMW parameters changed similarly in both groups during follow-up.
CONCLUSIONS: TAVI significantly influenced the majority of LVMW indices in the overall study population. Using the standard ID definition, ID had no impact on differences in LVMW indices. However, when defined by TSAT < 20%, patients with ID showed no significant post-TAVI changes in LVMW indices.
METHODS: We evaluated 100 patients with severe AS scheduled for TAVI between March 2021 and November 2022. All underwent ID screening according to the classic and novel ID definitions and echocardiographic assessment of LVMW before TAVI and at the 1-year follow-up.
RESULTS: Elimination of AS was observed within the 1-year follow-up in the whole population. Despite stable ejection fraction (EF) and global longitudinal strain (GLS), LVMW indices such as global work index (GWI) and global constructive work (GCW) significantly decreased from baseline in the entire population. However, when comparing ID and non-ID patients after the procedure, a statistically significant decrease in GWI and GCW was noted at the 1-year follow-up only in the TSAT > 20% group, not in the TSAT < 20% group. We also noted a significant correlation between TSAT status and echocardiographic as well as LVMW indices. When the classic ID definition was used, all LVMW parameters changed similarly in both groups during follow-up.
CONCLUSIONS: TAVI significantly influenced the majority of LVMW indices in the overall study population. Using the standard ID definition, ID had no impact on differences in LVMW indices. However, when defined by TSAT < 20%, patients with ID showed no significant post-TAVI changes in LVMW indices.
Предметные рубрики MeSH
Iron DeficienciesAortic Valve StenosisTranscatheter Aortic Valve ReplacementVentricular Dysfunction, LeftVentricular Function, LeftEchocardiographyHeart VentriclesFollow-Up StudiesStroke VolumeGlobal Longitudinal StrainTreatment OutcomeTime FactorsIronPrevalenceRetrospective StudiesHumansMaleFemaleAgedAged, 80 and overSeverity of Illness Index