DOI 10.2174/0118715265281114240131045945
Comparison of the Diagnostic Performance of Antigen B Purified from Sheep Hydatid Cyst Fluid (HCF) with Commercial ELISA Kit.
Аннотация
INTRODUCTION
Cystic echinococcosis (CE) is a zoonotic parasitic disease caused by the metacestode of Echinococcus granulosus. CE is a health problem in Middle Eastern countries, such as Iran. The purpose of this study was to purify subunit 8 KDa antigen B from crude sheep hydatid cyst fluid (HCF) and compare its sensitivity and specificity with a commercial human ELISA kit (PT-Hydatid-96).
METHODS
28 sera samples were collected from hydatid cyst patients who had surgery for a hydatid cyst and had their disease confirmed by pathology after the surgery. Furthermore, 35 samples of healthy individuals with no history of hydatid cysts were collected, as were nine serum samples from parasite-infected non-CE patients. HCF was obtained from sheep fertile cysts at a Sari slaughterhouse and used as an antigen. In an indirect ELISA test, the B antigen was employed, and the results were compared to those from a commercial ELISA kit.
RESULTS
The results of this study were analyzed using the Kappa test. The commercial ELISA kit showed 17 cases (23.6%) positive, 44 cases (61.1%) negative, and 11 cases (15.3%) borderline. B antigen showed that 18 (25%), 43 (59.7 %), and 11 (15.3%) were positive, negative, and borderline, respectively. One sample (1.4% of 72 total samples) of 35 serum samples from healthy individuals was positive using B antigen-based ELISA. In addition, all nine serum samples from parasite-infected non-CE patients were negative for both tests. The sensitivity and specificity of the commercial ELISA kit have been evaluated at 60.7% and 100%, respectively. For B antigenbased ELISA, these values are 64.3 and 97.7%, respectively.
CONCLUSION
Antigen B produced from hydatid cyst fluid is a promising option for serological identification of hydatid cysts in both infected and healthy individuals. In an indirect ELISA test, hydatid fluid antigen could be used as a precise source of detection.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.