MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/tomography11120139

Медицинская библиотека · Tomography (Ann Arbor, Mich.) · 2025

Aortic Valve Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increments: Impact on Calcium Severity Classifications.

Singh Mandeep, Moaddab Amirhossein, Shin Doosup, Weber Jonathan, Chau Karen, Dakroub Ali H, Parikh Roosha, Pipitone Karli, Ali Ziad A, Khalique Omar K

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

Aortic valve calcification is commonly evaluated using 3.0 mm true non-contrast (TNC) computed tomography (CT) images. This study evaluates the reproducibility of virtual non-contrast (VNC) reconstructions at different slice intervals using photon-counting detector CT (PCD-CT).

Methods

In this retrospective study, we included 279 consecutive patients, who underwent PCD-CT for evaluation of native aortic valve between February 2023 and December 2023 with both TNC and VNC images at 3.0 and 1.5 mm slice intervals. Aortic valve calcium score (AVCS) and aortic valve calcium volume (AVCV) were compared between the two methods using paired t-tests. Agreement for continuous variables was assessed using inter-class coefficients (ICCs). Cohen's Kappa (κ) was calculated to evaluate the agreement between different modalities in diagnosing severe AV calcification.

Results

Compared to the standard, TNC images at 1.5 mm intervals showed higher AVCS (mean difference: -290 ± 418, p < 0.001), with high reproducibility between techniques (CS: ICC 0.969, [IQR 0.962, 0.975]). Compared with reference, VNC showed no significant differences in AVCS at either slice intervals, with excellent reproducibility (3.0 mm, ICC 0.970 [0.963, 0.976]; 1.5 mm, ICC 0.971 [0.964, 0.977]). Compared to TNC 3.0 mm, strong concordance was observed using other reconstruction techniques in assessing severe AV calcification (κ = 0.81 [95% CI: 0.74-0.88], 0.83 [95% CI: 0.76-0.90], and 0.83 [95% CI: 0.76-0.90] for TNC at 1.5 mm, VNC at 3.0 mm, and 1.5 mm, respectively), with low misclassification rates.

Conclusions

Our study highlights high reproducibility in the evaluation of AVCS by VNC reconstruction at 3.0 and 1.5 mm intervals compared with reference offering a reliable alternative with an excellent diagnostic accuracy.

Для цитирования: Singh Mandeep, Moaddab Amirhossein, Shin Doosup, Weber Jonathan, Chau Karen, Dakroub Ali H, Parikh Roosha, Pipitone Karli, Ali Ziad A, Khalique Omar K. Aortic Valve Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increments: Impact on Calcium Severity Classifications.. Tomography (Ann Arbor, Mich.). 2025. DOI: 10.3390/tomography11120139.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.