BACKGROUND

Catheter ablation is the curative treatment for paroxysmal supraventricular tachycardia (SVT). However, atrial tachycardia (AT) diagnosis is often challenging, especially when SVT is terminated by pacing.

OBJECTIVES

This study sought to develop a novel method for AT diagnosis.

METHODS

A total of 147 SVTs including 28 ATs, 87 atrioventricular nodal re-entrant tachycardias, and 32 orthodromic reciprocating tachycardias were prospectively studied. Single atrial extrastimulation was performed at the proximal coronary sinus from a coupling interval 20 milliseconds shorter than the tachycardia cycle length and gradually decreased until the His bundle (HB) was first reset and further until the SVT was terminated. The response of the SVT during the first HB resetting and the termination pattern were examined.

RESULTS

In 27 of 28 ATs, tachycardia was unaffected when HB resetting whereas, in atrioventricular nodal re-entrant tachycardias or orthodromic reciprocating tachycardias (non-AT), tachycardia was simultaneously reset when HB resetting or was terminated with an atrio-Hisian block. When the coupling interval was further shortened for cases in which tachycardia persisted, all 33 SVTs with tachycardia termination with atrio-Hisian block were non-ATs, whereas 5 ATs and 7 non-ATs were terminated with Hisian-atrial block. The sensitivity, specificity, and positive and negative predictive values of the pattern of tachycardia that was unaffected when HB resetting for AT diagnosis were 96%, 100%, 100%, and 99%, respectively. Those of the pattern of tachycardia termination with atrio-Hisian block for non-AT diagnosis were 92%, 100%, 100%, and 42%, respectively.

CONCLUSIONS

Single atrial extrastimulation from the proximal coronary sinus during tachycardia was useful and effective for AT diagnosis.

Для цитирования: Inaba Osamu, Inamura Yukihiro, Takagi Takamitsu, Meguro Shin, Nakata Kentaro, Michishita Toshiki, Isonaga Yuhei, Kono Toshikazu, Tachibana Shinichi, Ikenouchi Takashi, Ohya Hiroaki, Murata Kazuya, Takamiya Tomomasa, Sato Akira, Sasano Tetsuo. A Single Atrial Extrastimulation Resetting His Bundle During Supraventricular Tachycardia to Differentiate Atrial Tachycardia.. JACC. Clinical electrophysiology. 2024. DOI: 10.1016/j.jacep.2024.02.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.