MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2025.11.018

Медицинская библиотека · Heart rhythm · 2025

Targetable atrial tachycardias after artificial intelligence-guided ablation of persistent atrial fibrillation.

Deisenhofer Isabel, Seitz Julien, Lotteau Sabine, Albenque Jean-Paul, Busch Sonia, Nguyen-Tu Marie-Sophie, Dayot Amélie, Dalmau Mélanie, Leukovich Hanna, Bars Clément, De Potter Tom, de Chillou Christian, Goldbarg Seth, Appetiti Anthony, Milpied Paola, Durdez Théophile Mohr, Hummel John D, Kalifa Jérôme

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The TAILORED-AF randomized trial demonstrated that artificial intelligence-guided ablation of spatiotemporal dispersion in addition to pulmonary vein isolation significantly reduced atrial fibrillation (AF) recurrence at 1-year follow-up in patients with persistent AF. Still, approximately one-third of the population experienced atrial tachycardia (AT) recurrences, most of which were successfully ablated.

OBJECTIVE

In this post hoc analysis of the TAILORED-AF trial, we determined the exact mechanism and locations of ATs and examined the adherence to protocol-recommended ablation and its relation to the occurrence of ATs.

METHODS

During index procedures, post-AF ATs were diagnosed based on common mapping and pacing maneuvers. Maps pertaining to activation and ablation lesions were evaluated by a panel of experts to assess compliance and completion of the TAILORED-AF protocol recommendations.

RESULTS

During the index procedure, 140 ATs (96 patients) were characterized including 76 macroreentrant ATs (29% perimitral, 42% peritricuspid, 20% roof dependent, 9% other), 37 localized ATs, 12 ATs with undetermined mechanisms, and 15 unstable ATs. The percentage of repeat ablations was significantly lower in patients who had a complete ablation set in common macroreentry AT regions (roof, mitral) ablation than patients with an incomplete ablation set (22% vs 48%; P = .02; odds ratio 0.31; 95% confidence interval 0.12-0.79).

CONCLUSION

Most ATs observed after artificial intelligence-guided, dispersion-based catheter ablation are targetable. The prevalence of these ATs and the repeat procedure rate are reduced when strategic completion of dispersion-based ablation was obtained.

Для цитирования: Deisenhofer Isabel, Seitz Julien, Lotteau Sabine, Albenque Jean-Paul, Busch Sonia, Nguyen-Tu Marie-Sophie, Dayot Amélie, Dalmau Mélanie, Leukovich Hanna, Bars Clément, De Potter Tom, de Chillou Christian, Goldbarg Seth, Appetiti Anthony, Milpied Paola, Durdez Théophile Mohr, Hummel John D, Kalifa Jérôme. Targetable atrial tachycardias after artificial intelligence-guided ablation of persistent atrial fibrillation.. Heart rhythm. 2025. DOI: 10.1016/j.hrthm.2025.11.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.