[Whether to implant a defibrillator or not? The Possibility of Using the MADIT-ICD Benefit Score Calculator in Real Practice].

Ilov N N, Boytsov S A, Nechepurenko A A

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

AIM: To study the predictive capabilities of the MADIT-ICD Benefit Score calculator in assessing the benefit of implantable cardioverter defibrillator (ICD) placement for the primary prevention of sudden cardiac death (SCD).

MATERIAL AND

METHODS

This study included 388 patients with NYHA II-IV functional class chronic heart failure (CHF) with a left ventricular ejection fraction (LVEF) ≤35 % who underwent ICD placement for the primary prevention of SCD. Patients were followed up for two years to record the endpoints of first-time paroxysmal sustained ventricular tachyarrhythmia (VT) or non-arrhythmic death.

RESULTS

According to the results of calculation with the MADIT-ICD Benefit Score calculator, 276 (71 %) patients had a high risk of VT (score ≥7) and 150 (39 %) had a high risk of non-arrhythmic death (score ≥3). 336 (94%) patients would benefit from an ICD: 148 (38 %) with a high level of probability and 218 (56 %) with a medium level of probability. According to the incidence of endpoints, VT episodes predominated in the low-ICD benefit group (36%), while the high-ICD benefit group had a relatively high incidence of non-arrhythmic death (12%).

CONCLUSION

The results obtained for a cohort of Russian patients with CHF and reduced LVEF indicated that the use of the MADIT-ICD Benefit Score in routine clinical practice does not improve the stratification of SCD risk compared to the traditional approach to selecting patients with CHF for ICD based on the LVEF value.

Для цитирования: Ilov N N, Boytsov S A, Nechepurenko A A. [Whether to implant a defibrillator or not? The Possibility of Using the MADIT-ICD Benefit Score Calculator in Real Practice].. Kardiologiia. 2024. DOI: 10.18087/cardio.2024.2.n2447.