DOI 10.1016/j.ijscr.2021.106174
Intra-abdominal propylene suture fragment leading to complete small bowel obstruction: A case report.
Аннотация
INTRODUCTION
Propylene sutures are non-absorbable sterile surgical sutures, which when present intra-abdominally act as a foreign body leading to adhesion formation. Post-operative adhesions are a common cause of bowel obstruction, with complete closed loop obstruction presenting as a surgical emergency.
CASE DETAILS: A 66-year-old man who had undergone a laparotomy for bowel obstruction two years back, presented to our emergency department with features of complete bowel obstruction. Midline laparotomy revealed propylene suture and intra peritoneal adhesions acting as a constricting band around the jejunum to be the cause.
DISCUSSION: Adhesions are common perturbing problem after surgeries. The presence of a foreign body further incites the process of adhesion formation by causing hindrance to the fibrinolysis process. In this case, the adhesive bands acted synergistically with the encircling prolene suture material from the previous surgery in causing a complete loop obstruction.
CONCLUSION
Propylene sutures used in routine surgical procedures can migrate intra-abdominally, and lead to adhesion formation. Adhesions along with the non-absorbable suture can cause complete bowel obstruction.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.