Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2016
Use of the Octopus Endograft Technique to Reconstruct Renovisceral Arteries Arising From the False Lumen of a Rapidly Expanding Type B Aortic Dissection After Endovascular Repair.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Xiong Jiang, Ge Yangyang, Liu Xiaoping, Wang Lijun, Guo Wei
Аннотация
PURPOSE: To describe the use and 6-month outcomes of the octopus endograft technique to reconstruct renovisceral arteries arising from the false lumen (FL) of a type B aortic dissection after thoracic endovascular aortic repair (TEVAR).
CASE REPORT: A 46-year-old man post TEVAR for type B aortic dissection was admitted with persistent back pain and a rapidly expanding residual dissection. The celiac and left renal arteries arose from the FL and the superior mesenteric artery from both lumens, with the FL as its main supply. A 20% oversized Endurant stent-graft was deployed with the short limb just above the beginning of the dissection flap and the long limb in the aortic true lumen. A 120-mm-long Endurant extended limb was delivered antegradely via a conduit and deployed into the FL, with a 3-cm overlap with the short limb of the Endurant main body. The 3 renovisceral arteries were reconstructed by lining each with a series of Viabahn or Fluency stent-grafts whose proximal ends were subsequently placed parallel in the FL Endurant extended limb and dilated with kissing balloons. Imaging at 6 months showed an excluded FL, without stenosis or occlusion in the stent-graft or the renovisceral arteries.
CONCLUSION: This case illustrates the successful use of the octopus endograft technique to reconstruct renovisceral arteries arising from a rapidly expanding FL in a post-TEVAR type B aortic dissection; the technique might be applicable in carefully selected patients.
CASE REPORT: A 46-year-old man post TEVAR for type B aortic dissection was admitted with persistent back pain and a rapidly expanding residual dissection. The celiac and left renal arteries arose from the FL and the superior mesenteric artery from both lumens, with the FL as its main supply. A 20% oversized Endurant stent-graft was deployed with the short limb just above the beginning of the dissection flap and the long limb in the aortic true lumen. A 120-mm-long Endurant extended limb was delivered antegradely via a conduit and deployed into the FL, with a 3-cm overlap with the short limb of the Endurant main body. The 3 renovisceral arteries were reconstructed by lining each with a series of Viabahn or Fluency stent-grafts whose proximal ends were subsequently placed parallel in the FL Endurant extended limb and dilated with kissing balloons. Imaging at 6 months showed an excluded FL, without stenosis or occlusion in the stent-graft or the renovisceral arteries.
CONCLUSION: This case illustrates the successful use of the octopus endograft technique to reconstruct renovisceral arteries arising from a rapidly expanding FL in a post-TEVAR type B aortic dissection; the technique might be applicable in carefully selected patients.