Cannon A wave validation as a diagnostic tool in paroxysmal supraventricular tachycardias.

González-Casal David, Pérez-Castellanos Alberto, Flores Nina Soto, Carta-Bergaz Alejandro, González-Torrecilla Esteban, Bruña Fernández Vanesa, Ávila Pablo, Atienza Felipe, Arenal Ángel, González-Panizo Jorge, Fernández-Avilés Francisco, Cabrera José Angel, Datino Tomás

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The presence of cannon A waves, the so called "frog sign", has traditionally been considered diagnostic of atrioventricular nodal re-entrant tachycardia (AVNRT). Nevertheless, it has never been systematically evaluated. The aim of this study is to assess the independent diagnostic utility of cannon A waves in the differential diagnosis of supraventricular tachycardias (SVTs).

METHODS

We prospectively included 100 patients who underwent an electrophysiology (EP) study for SVT. The right jugular venous pulse was recorded during the study. In 61 patients, invasive central venous pressure (CVP) was registered as well. CVP increase is thought to be related with the timing between atria and ventricle depolarization; two groups were prespecified, the short VA interval tachycardias (including typical AVNRT and atrioventricular reciprocating tachycardia (AVRT) mediated by a septal accessory pathway) and the long VA interval tachycardias (including atypical AVNRT and AVRT mediated by a left free wall accessory pathway).

RESULTS

The relationship between cannon A waves and AVNRT did not reach the statistical significance (OR: 3.01; p = .058); On the other hand, it was clearly associated with the final diagnosis of a short VA interval tachycardia (OR: 10.21; p < .001). CVP increase showed an inversely proportional relationship with the VA interval during tachycardia (b = -.020; p < .001). CVP increase was larger in cases of AVNRT (4.0 mmHg vs. 1.2 mmHg; p < .001) and short VA interval tachycardias (3.9 mmHg vs. 1.2 mmHg; p < .001).

CONCLUSION

The presence of cannon A waves is associated with the final diagnosis of short VA interval tachycardias.

Для цитирования: González-Casal David, Pérez-Castellanos Alberto, Flores Nina Soto, Carta-Bergaz Alejandro, González-Torrecilla Esteban, Bruña Fernández Vanesa, Ávila Pablo, Atienza Felipe, Arenal Ángel, González-Panizo Jorge, Fernández-Avilés Francisco, Cabrera José Angel, Datino Tomás. Cannon A wave validation as a diagnostic tool in paroxysmal supraventricular tachycardias.. Pacing and clinical electrophysiology : PACE. 2024. DOI: 10.1111/pace.14946.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.