MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/der.0000000000000672

Медицинская библиотека · Dermatitis : contact, atopic, occupational, drug · 2021

Isothiazolinone Detection in Dish Soap and Personal Care Products: Comparison of Lovibond Isothiazolinone Test Kit and Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry.

Kimyon Rebecca S, Zang Lun-Yi, Siegel Paul D, Voller Lindsey M, Schlarbaum Jamie P, Warshaw Erin M

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Isothiazolinones are commonly used preservatives, which may cause allergic contact dermatitis. The Lovibond Isothiazolinone Test Kit (LITK) has been reported to successfully identify clinically relevant, occult isothiazolinones in patient personal care products.

OBJECTIVE

The aim of the study was to analyze dish soaps and personal care products that do not declare isothiazolinones ("no-ISO") for the presence of isothiazolinones via 2 methods: LITK and ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS).

METHODS

No-ISO dish soaps (n = 9), a convenience sample of patient products (n = 6), and controls (positive [isothiazolinone declared], n = 5; negative, n = 2) were tested with LITK (X3) and UHPLC-MS/MS.

RESULTS

Several no-ISO dish soaps and personal products were positive for isothiazolinones (LITK, n = 12; UHPLC-MS/MS, n = 3). Ultrahigh-performance liquid chromatography-tandem mass spectrometry specifically identified methylisothiazolinone alone in 1 no-ISO dish soap, methylchloroisothiazolinone in another, and both in a third. Using UHPLC-MS/MS as the criterion standard, we observed the accuracy of LITK for 9 dish soaps was poor (sensitivity, 66.7%; specificity, 20%) and very poor for 6 personal care products (sensitivity, 0%; specificity, 0%).

CONCLUSIONS

Personal products may contain undeclared isothiazolinones. The current study found that LITK had poor accuracy for testing dish soap and personal care products. Clinicians should be aware of these factors when managing patients with contact allergy to isothiazolinones.

Для цитирования: Kimyon Rebecca S, Zang Lun-Yi, Siegel Paul D, Voller Lindsey M, Schlarbaum Jamie P, Warshaw Erin M. Isothiazolinone Detection in Dish Soap and Personal Care Products: Comparison of Lovibond Isothiazolinone Test Kit and Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry.. Dermatitis : contact, atopic, occupational, drug. 2021. DOI: 10.1097/der.0000000000000672.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.