MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ndt/gfm190

Медицинская библиотека · Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2007

Machine-generated bicarbonate dialysate for continuous therapy: a prospective, observational cohort study.

Teo Boon Wee, Demirjian Sevag, Meyer Kathryn H, Wright Eugene, Paganini Emil P

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In 1995, we described the technique of adapting a haemodialysis (HD) machine to produce a composition-adjustable, bicarbonate-based fluid (as our primary source for dialysate) for continuous HD in intensive care unit (ICU) patients with acute renal failure (ARF). The following studies the clinical effects, biochemical changes and economic costs of this practice in a large cohort of patients at a single centre over the last 10 years.

METHODS

The CCF-ARF Support Registry (1995-2001) was used to identify 405 patients initially supported with bicarbonate continuous HD. The registry is a prospective, observational cohort database that captures demographic, dialysis therapy, laboratory and outcome data. All supported ARF patients were recorded from 1995-98, and then one in five patients from 1999 to 2001. We also reviewed records of the individual dialysis procedures, dialysate disposal, dialysate monitoring tests and specific costs.

RESULTS

Continuous HD was performed for 1292 +/- 587 days from 1994 to 2004. Demographics [age 59.57 +/- 14.41 years, weight 84.2 +/- 24 kg, male 65%, chronic kidney disease (CKD) 34%] and ICU mortality (60.5%) were comparable to other reported series. Day 4 solute [BUN 52.3 mg/dl (95% CI 49.6-54.9), creatinine 2.79 mg/dl (95% CI 2.64-2.95)], electrolyte and acid-base balance [bicarbonate 24.12 mmol/l (95% CI 23.7-24.6)] were well controlled. Dialysate monitoring revealed no positive cultures or elevated endotoxin levels. Variable-composition dialysate was achieved and delivered to all patients without adverse consequences. The cost of dialysate actually declined over time (1995 = $0.91/l, 2005 = $0.67/l).

CONCLUSION

We have demonstrated that ICU ARF patients can be safely, effectively and economically supported with continuous HD using this source.

Для цитирования: Teo Boon Wee, Demirjian Sevag, Meyer Kathryn H, Wright Eugene, Paganini Emil P. Machine-generated bicarbonate dialysate for continuous therapy: a prospective, observational cohort study.. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 2007. DOI: 10.1093/ndt/gfm190.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.