Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2016
The Loop Technique: Addressing Celiac Artery Dissection in a Branched and Fenestrated Endograft for the Treatment of a Type III Thoracoabdominal Aneurysm.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Erben Young, Oderich Gustavo S, Gloviczki Peter
Аннотация
PURPOSE: To describe a bailout technique for use during branched/fenestrated thoracoabdominal aortic aneurysm (TAAA) repair to address celiac artery (CA) dissection.
TECHNIQUE: The technique is demonstrated in a 69-year-old man who underwent fenestrated stent-graft repair of a 6-cm type III TAAA. The main fenestrated stent-graft was positioned without difficulty, and the renal and superior mesenteric arteries were stented. A stent-graft was placed in the CA, but angiography showed the vessel to be occluded by dissection beyond the stent-graft. Wire manipulations to regain access to the true lumen culminated in perforation. At this point, the gastroduodenal artery was catheterized with a 0.035-inch guidewire, which was advanced in retrograde fashion into the CA true lumen and then snared back to the left brachial artery forming a loop. After exchange for a 0.014-inch system, self-expanding stents were deployed into the hepatic artery. Postoperative recovery was uneventful, and the patient was discharged on day 6. At 1-year follow-up, the patient was doing very well. Imaging demonstrated no endoleak, no graft migration, and sac shrinkage to a diameter of 5.1 cm.
CONCLUSION: The "loop technique" can be a very useful and effective bailout maneuver in regaining access to the true lumen of a dissected CA in patients undergoing branched/fenestrated thoracoabdominal aortic aneurysm repair.
TECHNIQUE: The technique is demonstrated in a 69-year-old man who underwent fenestrated stent-graft repair of a 6-cm type III TAAA. The main fenestrated stent-graft was positioned without difficulty, and the renal and superior mesenteric arteries were stented. A stent-graft was placed in the CA, but angiography showed the vessel to be occluded by dissection beyond the stent-graft. Wire manipulations to regain access to the true lumen culminated in perforation. At this point, the gastroduodenal artery was catheterized with a 0.035-inch guidewire, which was advanced in retrograde fashion into the CA true lumen and then snared back to the left brachial artery forming a loop. After exchange for a 0.014-inch system, self-expanding stents were deployed into the hepatic artery. Postoperative recovery was uneventful, and the patient was discharged on day 6. At 1-year follow-up, the patient was doing very well. Imaging demonstrated no endoleak, no graft migration, and sac shrinkage to a diameter of 5.1 cm.
CONCLUSION: The "loop technique" can be a very useful and effective bailout maneuver in regaining access to the true lumen of a dissected CA in patients undergoing branched/fenestrated thoracoabdominal aortic aneurysm repair.
Предметные рубрики MeSH
AgedAortic DissectionAortic Aneurysm, ThoracicAortographyBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationBrachial ArteryCatheterization, PeripheralCeliac ArteryComputed Tomography AngiographyDuodenumEndovascular ProceduresHepatic ArteryHumansMaleProsthesis DesignStentsStomachTreatment Outcome