Are vitamin B-12 measurements adequate for evaluating its deficiency in individuals?

Özdemir Sedat, Demirtaş Selda

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Measurement of vitamin B-12 deficiency using different methods may cause diagnostic difficulties. In order to rapidly and safely diagnose vitamin B-12 deficiency, it is important to determine the reference ranges of serum B-12 and its related biomarkers such as homocysteine, holotranscobalamine (holo-TC) and methylmalonic acid (MMA). This study aimed to determine reference interval (RI)s for serum vitamin B-12 and related markers.

METHODS AND STUDY

DESIGN

Samples were collected from 404 young-to-middle-aged healthy adults aged 18-65 years. Vitamin B-12, homocysteine, holotranscobalamin, folate were analyzed using the Arcitect i2000 device. Plasma MMA was analyzed by LC/MS. RIs were then evaluated accordingly.

RESULTS

Vitamin B-12, folate, homocysteine, holotranscobalamin and plasma MMA were 139-619 pg/mL, 3.0-14.7 ng/mL, 5.6-18.4 μmol/L, 10.7-101 pmol/L, and 0.01-0.8 μmol/L, respectively. Age group-specific RIs were also generated.

CONCLUSIONS

This study revealed that the diagnosis of vitamin B-12 deficiency should not only be based on serum vitamin B-12 levels, but also of folate, homocysteine, holotranscobalamin and MMA levels; all which are related to vitamin B-12 metabolism.

Для цитирования: Özdemir Sedat, Demirtaş Selda. Are vitamin B-12 measurements adequate for evaluating its deficiency in individuals?. Asia Pacific journal of clinical nutrition. 2025. DOI: 10.6133/apjcn.202504_34(2).0010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.